Power supply | 12 to 24 V DC ±10% / Ripple 10% or less |
---|---|
Power consumption | Normal mode : 770 mW or less (32 mA or less at 24 V) ECO mode : 600 mW or less (25 mA or less at 24 V) |
Control output | NPN open collector output / Load current 100 mA (30 V DC) or less / Residual voltage: 1 V or less PNP open collector output / Load current 100 mA (30 V DC) or less / Residual voltage: 2 V or less |
Operation mode | Light ON/Dark ON |
Timer | ON delay / OFF delay / ON/OFF delay / One shot/ No timer Delay timer: 1 to 9999 ms (set in milliseconds) |
Response time | High speed mode: 65 μs or less / Standard mode: 500 μs or less / Long mode: 4 ms or less |
Light source (wavelength) | Four-element (AlGaInp) red LED (660 nm) |
Indicator | Operation indicator, Setting indicator, Light ON / Dark ON indicator: orange LED |
Display | Received light level: 4 digits in red LED (high-speed mode (0 to 3500), standard / long mode (0 to 9999)) Threshold: 4 digits in green LED (high-speed mode (0 to 3300), standard / long mode (0 to 9700)) |
Switch | Teaching and set switch (SET) Switch for threshold adjustment (UP/DOWN) |
Sensitivity setting | 2-point teaching / Max. sensitivity teaching / Full auto teaching / Position teaching |
Sensitivity adjustment function | Provided (manual adjustment) |
Sensitivity adjustment function | Provideed |
Mutual Interference prevention | UP to 8 units (standard / long mode) |
Protection circuit | Power supply reverse connection protection / Output short circuit protection |
Material | Polycarbonate |
Wiring | 2 m attached cable (Outer dimension: dia. 4.2 mm) 0.2 mm2, 4 cores |
Weight | Approx. 75 g |
Accessory | Instruction maual / QR code label for simplified manual |
* When using as UL approved equipment
Ambient light | Illumination on light receiving surface: 3,500 lx or less (incandescent lamp) |
---|---|
Ambient temperature | 1 to 5 adjacent units in operation : -25 to +55°C 6 to 26 adjacent units in operation : -25 to +50°C *1 Storage : -40 to +70°C (non-freezing, non-condensing) |
Ambient humidity | 35 to 85% RH (non-condensing) |
Protective structure | IP40 |
Vibration | 10 to 55 Hz / 1.5 mm double amplitude / 2 hours each in X, Y, and Z directions |
Shock | 500 m/s2 / 3 times each in X, Y and Z directions |
Dielectric withstanding | 1000 V AC for 1 minute |
Insulation resistance | 500 V DC mega, 20 MΩ or more |
*1 : UL: Maximum ambient temperature: +55℃ for single use, +45℃ for two or more units connected installation.