Rating/Performance/Specification

Detection method Through beam
Detecting distance 1 m
Detection object dia.3mm (or more) Opaque
Power supply 12VDC±10%
Current consumption Transmitter : 15mA or less
Receiver : 15mA or less
Output mode PNP open collector
Rating: source current 80mA (30 VDC) or less
Operation mode (See the Type table in the previous page)
Response time 0.5ms or less
Light source Infrared
Indicator Transmitter: -
Receiver: Operation indicator (red LED), Stability indicator (green LED)
Material Case : LCP (filler:PP)
Lens : PMMA
Connection Attached cable (dia. 2.5)
Transmitter: 0.15 mm2 x 2 cores 2m (gray)
Receiver: 0.15 mm2 x 3 cores 2m (black)
Weight Transmitter : Approx. 30g
Receiver : Approx. 30g
Notes * The distance between the sensor and the in-line volume for sensitivity adjustment is fixed to 300mm.
Accessory Instruction manual, screw(M2×10mm),nuts and washers

Environmental Specification

Ambient light 3,000 lx or less
Ambient temperature -25 - +55 ℃ (non-freezing)
Ambient humidity 35-85%RH (non-condensing)
Protective structure IP64
Vibration 10 - 55 Hz / 1.5 mm double amplitude / 2 hours each in 3 direction