Detection method | Through beam |
---|---|
Detecting distance | 0.5-2.5m |
Detection object | Opaque dia.13 mm or more |
No. of light axes | 10 |
Detecting width | 100mm |
Optical axis interval | 11mm |
Power supply | 12 - 24V DC ±10% / Ripple 10% or less |
Current consumption | Transmitter: 80mA or less Receiver: 110mA or less * |
Output mode | PNP open collector Rating: source current 100mA (30 VDC or less) |
Operation mode | Activated when light beams of all axes are received (deactivated when light beam of any axis is blocked)*1 |
Response time | Light blocking :5ms or less Light reception 8ms or less |
Light source (wavelength) | Infrared LED (870nm) |
Indicator | Transmitter: Power indicator (Green LED) Receiver: Power indicator (Green LED) / Operation indicator ( Orange LED) |
Short circuit protection | Provided |
Material | Case body: Aluminum / Caps at ends: glass fiber filled PBT / Froht cover : Acrylic |
Connection | Attached cable (dia.4 mm) 3 m Cable: 0.3 mm2 x 2 cores, gray (transmitter) or 0.3 mm2 x 3 cores, black (receiver) |
Weight | Approx. 130 g (transmitter/receiver) |
Accessory | Operation manual (Note) Mounting brackets are not provided |
Notes | *The receiver current consumption shown is for 12 VDC. When the voltage is 24 VDC, the consumption is reduced to about 60%. *1 "-D" types, or models deactivated when light beams of all axes are received, are also available. |
*The receiver current consumption shown is for 12 VDC. When the voltage is 24 VDC, the consumption is reduced to about 60%. *1 "-D" types, or models deactivated when light beams of all axes are received, are also available.
Ambient light | 5,000lx or less |
---|---|
Ambient temperature | -10 - +55 ℃ (non-freezing) |
Ambient humidity | 35-85%RH (non-condensing) |
Protective structure | IP67 |
Vibration | 10-55 Hz / 1.5 mm double amplitude / 2 hours each in 3 directions |
Shock | 500 m/s2 / Twice each in 3 directions |
Dielectric withstanding | 500 VAC for 1 minute |
Insulation resistance | 500 VDC, 20 MΩ or higher. |