DMC-A4A

Specification

Power supply 24VDC±10%
Current consumption 40mA or less
A/D conversion method Sequential comparison system 10bit (1024)
Measurement range (input mode) 0 to 5 VDC/0 to 10 VDC /0 to 20mA (selectable)
Display resolution 0 to 5VDC :0.01V/0 to 10 VDC :0.01V / 0 to 20mA : 0.1mA
Output mode NPN open collector output, Rating: 50mA (30VDC) or less, 4 output
Sensor power supply 24VDC (200mA or less) ※1
Indication method 3 digits, 0 to 5V : 0.00 to 5.50/0 to 10V : 0.00 to 11.0/0 to 20mA : 0.00 to 22.0
Indication size 7 segments, Red×1, Green×3, Font size: 8×4mm
Sampling speed 2000 times/sec
Avaraging 1 to 200 counts (selectable)
Output delay On delay/Off delay (1 to 999msec, selectable)
Operation mode HI ON (Hon) / LO ON (Lon) (selectable)
Connection Terminal block, Tightening torque: 0.3N・m or less
Material Case: PPE Panel: PET
Mounting method DIN rail (35mm) and screw tightening method
Weight Approx. 130g
Accessories Instruction manual

※1 Power supply directly connected

Environmental specification

Ambient temperature -10 to +55℃ (non-freezing)
Ambient humidity 35 to 85%RH (non-condensing)
Vibration When mounting directly, When mounting to DIN :
10 to 55Hz when tested with double amplitude of 0.75mm in X, Y, and Z directions, 2 hours for each direction ※2
Shock When mounting directly : 500m/s2 when tested in X, Y, and Z directions, 3 times for each direction
When mounting to DIN : 300m/s2 when tested in X, Y, and Z directions, 3 times for each direction
Dielectric tolerance 1000VAC for 1 minute between whole live part and case
Insulation resistance 20MΩ or more when tested with 500VDC megger

※2 When mounting to the DIN rail, attach the stopper (end unit) to the product.
End unit (option) model : FA7EU