| TYPE |
Plug-in (2-channel) |
| Model |
SRB20 |
| Bit count |
20bit (10bit x 2) |
| Power supply |
100-120V, 200-240VAC ±10% 50/60Hz |
| Power consumption |
3VA max. |
| Input signal(common to all inputs) |
Open collector: L level: ON; H level: OFF
Voltage: L level: 0-2 V; H level: 6-30 V
Contact: L level: ON; H level: OFF |
| Data output |
TRIGGER (T) mode: temporarily stored at H -> L (fall)
LEVEL (L) mode: active at L level
Minimum input pulse width: 25 ms |
| Shift input |
Shift at H -> L (fall)
Minimum input pulse width: 25 ms |
| Reset input |
Reset at L level
Minimum input pulse width: 25 ms |
| Position of output |
● Parallel mode
Ch 1 data input Ch 1 output variable between 1-10 bits
Ch 2 data input Ch 2 output variable between 11-20 bits
● Serial mode
Ch 1: data input Ch 1: variable between 1-10 bits
Ch 2: variable between 1-10 bits |
| Operation mode |
ON-OFF operation |
| Output mode |
Relay output 1a, 2 channels
Rating: 1 A (250 VAC) resistance load |
| Power supply to sensor |
12V DC 100mA |
| Power failure compensation |
Ni-Cd storage battery backup |
| Power failure compensation time |
80 hours after supplying power for 8 hours |
| Connection |
Terminal block (with M3.5 screws) |
| Case material |
Polycarbonate |
| Mass |
440g max. |
| Notes |
See Panel Description for indicators, switches, etc. |