| Model |
DX-S400 |
| Installation height (above floor) |
1 to 4m (*1) |
| Detection height (above floor) |
Approx. 0.4m min (*2) |
| Standard detection object |
White paper of φ0.3m |
| Power supply |
12 to 24 VDC ±10% / Ripple 10% or less |
| Current consumption |
1.3 W or less |
| Output mode |
Relay output: 1C Rating : 0.5A 30VDC or less (resistance load) |
| Operating mode |
Still mode/Passing mode selection operation |
| Timer |
No timer/ON-OFF delay selection
Timer: 3/9 s selectable |
| Response time |
Still mode: 1.5s or less, Passing mode: 0.2s or less |
| Prevention of mutual interference |
Master/slave (MAX. 8 units including a master unit) |
| Light source (wave length) |
Red LED (850 nm) |
| Indicator |
POWER/TEACH indicator: Yellow green LED
OPERATION indicator: Green LED
ERROR/SLAVE indicator: Orange LED
ZONE indicator: Yellow LED |
| Switch |
SET switch (Power ON reset teaching ON/OFF switch)
DELAY switch (timer switch)
ZONE switch (zone switch) |
| Teaching method |
Power ON reset teaching
Teaching with a remote controller
(Remote controller is optional) |
| Teaching type |
One point zone teaching |
| Materials |
Base: ABS resin
Chassis: ABS resin
Cover: Acrylic |
| Wiring |
M3 self-up terminal block |
| Weight |
Approx. 200g |
| Accessories |
Mounting screw, dust prevention sheet, instruction manual |
*1: When the floor is made of asphalt, install at 1 to 3.1m above the floor.
*2: Approx. 0.4 to 0.7m or more is set automatically by the automatic sensitivity correction function.
DX-S300W Rating/Performance/Specifications
| Model |
DX-S300W |
| Installation height (above floor) |
1 to 3m (*3) |
| Detection height (above floor) |
Approx. 0.4m min (*4) |
| Standard detection object |
White paper of φ0.3m |
| Power supply |
12 to 24 VDC ±10% / Ripple 10% or less |
| Current consumption |
1.7 W or less |
| Output mode |
Relay output: 1C Rating : 0.5A 30VDC or less (resistance load) |
| Operating mode |
Still mode/Passing mode selection operation |
| Timer |
No timer/ON-OFF delay selection
Timer: 3/9 s selectable |
| Response time |
Still mode: 1.5s or less, Passing mode: 0.2s or less |
| Prevention of mutual interference |
Master/slave (MAX. 8 units including a master unit) |
| Light source (wave length) |
Red LED (850 nm) |
| Indicator |
OPERATION/TEACH indicator: Yellow green LED
ERROR/SLAVE indicator: Orange LED
ZONE indicator: Yellow LED |
| Switch |
SET switch (Power ON reset teaching ON/OFF switch)
DELAY switch (timer switch)
ZONE switch (zone switch) |
| Teaching method |
Power ON reset teaching
Teaching with a remote controller
(Remote controller is optional) |
| Teaching type |
One point zone teaching |
| Materials |
Base: ABS resin
Chassis: ABS resin
Cover: Acrylic |
| Wiring |
M3 self-up terminal block |
| Weight |
Approx. 200g |
| Accessories |
Mounting screw, dust prevention sheet, instruction manual |
*3: When the floor is made of asphalt, install at 1 to 2.6m above the floor.
*4: Approx. 0.4 to 1m or more is set automatically by the automatic sensitivity correction function.
Environmental specification (DX-S400/DX-S300W)
| Ambient light |
5,000 lx or less |
| Ambient temperature |
-20 to +55°C (at storage: -40 to +70°C) (non-freezing) |
| Ambient humidity |
35 to 85 % RH (non-condensing) |
| Protective structure |
IP 40 |
| Vibration resistance |
10 to 55Hz Double amplitude width 1.5mm X,Y,Z directions for 2 hours respectively |
| Impact resistance |
500m/s2 X,Y,Z directions for three times respectively |
| Withstand voltage |
1000 VAC for 1 minute |
| Insulation resistance |
20 MΩ min. with 500 VDC mega |
|