Home > Products Info > Products for Specific Application > DX-S400/DX-S300W
| DX-S400 | GT2(S)-WS | F70A-WS | F1RM-DR | GT2S-DR | LST | DW-S | ASW-SG | ASW |
DX-S400/DX-S300W
DX-S400
 
  • New evolution type of sensor for parking lot
  • Detection for Zone passage or motionless object
 
DIMENSIONS HOW TO CONNECT DXF

Detection area

DX-S400 Detection area

Applications

DX-S400/DX-S300W Applications

Feautures

No dead zone

Less influence by body shape and color

No influence by multi- reflection

No influence by temperature change and wind

Less influence by snow

DX-S400 Rating/Performance/Specifications

Model DX-S400
Installation height (above floor) 1 to 4m (*1)
Detection height (above floor) Approx. 0.4m min (*2)
Standard detection object White paper of φ0.3m
Power supply 12 to 24 VDC ±10% / Ripple 10% or less
Current consumption 1.3 W or less
Output mode Relay output: 1C Rating : 0.5A 30VDC or less (resistance load)
Operating mode Still mode/Passing mode selection operation
Timer No timer/ON-OFF delay selection
Timer: 3/9 s selectable
Response time Still mode: 1.5s or less, Passing mode: 0.2s or less
Prevention of mutual interference Master/slave (MAX. 8 units including a master unit)
Light source (wave length) Red LED (850 nm)
Indicator POWER/TEACH indicator: Yellow green LED
OPERATION indicator: Green LED
ERROR/SLAVE indicator: Orange LED
ZONE indicator: Yellow LED
Switch SET switch (Power ON reset teaching ON/OFF switch)
DELAY switch (timer switch)
ZONE switch (zone switch)
Teaching method Power ON reset teaching
Teaching with a remote controller
(Remote controller is optional)
Teaching type One point zone teaching
Materials Base: ABS resin
Chassis: ABS resin
Cover: Acrylic
Wiring M3 self-up terminal block
Weight Approx. 200g
Accessories Mounting screw, dust prevention sheet, instruction manual

*1: When the floor is made of asphalt, install at 1 to 3.1m above the floor.
*2: Approx. 0.4 to 0.7m or more is set automatically by the automatic sensitivity correction function.

DX-S300W Rating/Performance/Specifications

Model DX-S300W
Installation height (above floor) 1 to 3m (*3)
Detection height (above floor) Approx. 0.4m min (*4)
Standard detection object White paper of φ0.3m
Power supply 12 to 24 VDC ±10% / Ripple 10% or less
Current consumption 1.7 W or less
Output mode Relay output: 1C Rating : 0.5A 30VDC or less (resistance load)
Operating mode Still mode/Passing mode selection operation
Timer No timer/ON-OFF delay selection
Timer: 3/9 s selectable
Response time Still mode: 1.5s or less, Passing mode: 0.2s or less
Prevention of mutual interference Master/slave (MAX. 8 units including a master unit)
Light source (wave length) Red LED (850 nm)
Indicator OPERATION/TEACH indicator: Yellow green LED
ERROR/SLAVE indicator: Orange LED
ZONE indicator: Yellow LED
Switch SET switch (Power ON reset teaching ON/OFF switch)
DELAY switch (timer switch)
ZONE switch (zone switch)
Teaching method Power ON reset teaching
Teaching with a remote controller
(Remote controller is optional)
Teaching type One point zone teaching
Materials Base: ABS resin
Chassis: ABS resin
Cover: Acrylic
Wiring M3 self-up terminal block
Weight Approx. 200g
Accessories Mounting screw, dust prevention sheet, instruction manual

*3: When the floor is made of asphalt, install at 1 to 2.6m above the floor.
*4: Approx. 0.4 to 1m or more is set automatically by the automatic sensitivity correction function.

Environmental specification (DX-S400/DX-S300W)

Ambient light 5,000 lx or less
Ambient temperature -20 to +55°C (at storage: -40 to +70°C) (non-freezing)
Ambient humidity 35 to 85 % RH (non-condensing)
Protective structure IP 40
Vibration resistance 10 to 55Hz Double amplitude width 1.5mm X,Y,Z directions for 2 hours respectively
Impact resistance 500m/s2 X,Y,Z directions for three times respectively
Withstand voltage 1000 VAC for 1 minute
Insulation resistance 20 MΩ min. with 500 VDC mega
 