Home > Products Info > Photo sensors for Steel & Heavy industries > FD-A320 Series
HMD | FD-A320 | FD-A300P | FD300A/600A | FD-A310C | FD-A300AN | KD150C | KD50 | HD |
CMD | FT44A | FT10A | FT101 | NT | KL(R)50 |
Punch hole detection sensor | SWD55 | SWD60 |
FD-A320 series
FD-A320
 
  • Dual digital display for threshold and incident level
  • Wide dynamic range -----From low to high temperature with a single sensor
  • Equipment of simulation function by means of external input.
  • Adoption of highly-reliable hermetically sealed contact Bestact relay (FD-A320H)
    (Bestact Relay is a registered trademark of the Yaskawa Controls Co., Ltd.)
  • Equipment of 4-20mA current output
 
DIMENSIONS OUTPUT CIRCUIT DXF
Specifications
Model FD-A320 FD-A320H
Type of output Relay Output PhotoMOS Relay Output Bestact Relay Output PhotoMOS Relay Output
Operation Mode ON-OFF control
Light ON
Rating Transfer contact 1c MAX 5A 250V AC (Resistive Load) 1a MAX 0.1A 250V AC/DC (Resistive Load) 1a 0.5A 220V AC 0.3A 110VDC (Inductive load) 1a MAX 0.1A 250V AC/DC (Resistive Load)
Response
time
Relay Output:
17ms or less
PhotoMOS Relay Output:
4ms or less
Bestact Relay Output:
6ms or less
PhotoMOS Relay Output:
4ms or less
Stability output Operation Mode After seven consecutive runs with less margin for the threshold light intensity
Rating Relay Output: 1a MAX 5A 250V AC (Resistive Load)
PhotoMOS Relay Output: 1a MAX 0.1A 250V AC/DC (Resistive Load)
Current Operation Mode:4mA to 20mA analog signals (Allowable load resistance : 0 to 500Ω)
Response time 4ms or less F.S
Valid Lens Aperture 28mm DIA (OHA/OHAN/OHAN10)
Power supply AC100 to 240V +10% -15% 50/60Hz
Power Consumption 6W or less
Connection Method Connector type leaded 2m wire (VCTF 0.75sq x 16c)
Ambient temperature Optical head /Optical Fiber Unit: -25 to +200℃
Amplifier unit : -25 to +50℃ (with no icing)
Storage temperature -40 to +70℃(with no condensation and no icing)
Ambient humidity 35 to 85% RH (with no condensation)
Bending limit of
optical fiber unit
50mm radius
Insulation
resistance
Power supply to Case :20MΩ or more at 500VDC,
Control Output・Stabiliy Output to Case :20MΩ or more at 500VDC
Power supply to Control Output・Stabiliy Output :20MΩ or more at 500VDC
Case to 4mA-20mA Output :20MΩ or more at 500VDC,
Power supply to 4mA-20mA Output :20MΩ or more at 500VDC
Case to Simulation Input :20MΩ or more at 500VDC,
Power supply to Simulation Input :20MΩ or more at 500VDC
Dielectric
strength
Power supply to Case :1500V AC 1 min (10mA)
Case to Control Output・Stabiliy Output :1500V AC 1 min (10mA)
Power supply to Control Outputstrength ・Stabiliy Output :1500V AC 1 min (10mA)
Case to 4mA-20mA Output :500V AC 1 min (20mA) ,
Power supply to 4mA-20mA Output :500V AC 1 min (20mA)
Case to Simulation Input :500V AC 1 min (20mA),
Power supply to Simulation Input :500V AC 1 min (20mA)
Vibration resistance 10 - 55Hz Single amplitude 1.5mm 2hours
each in X.Y.Z. directions
Shock resistance 500 m/s2 (Approx.50G) Three times each in X.Y.Z. directions
Protective Construction IP64
Mass Optical head Standard type (OHA):Approx. 680g
Narrow type (OHAN) :Approx. 840g Narrow type (OHAN10):Approx. 860g
Wide type (OHW1/OHW2): Approx.1300g
Airless Hood               F38A : Approx. 240g      F38A-03: Approx. 430g
               F38A -04 : Approx. 550    F38A-05: Approx. 650g
F38W : Approx. 600g
Air Purge Hood F38PC-02 : Approx. 240g F38PC-05: Approx. 440g
F38PC-03 : Approx. 300g 302W : Approx. 600g
F38PC-04 : Approx. 370g
Optical Fiber
Unit
(FG series)
FG2 :Approx. 0.7 kg FG3 :Approx. 0.9 kg FG4 :Approx. 1.1 kg
FG5 :Approx. 1.3 kg FG7 :Approx. 1.6 kg FG10 :Approx. 2.1 kg
FG15 :Approx. 3.1 kg FG20 :Approx. 4.1 kg FG30 :Approx. 6.1 kg
Amplifier
Unit
Amplifier Unit : Approx.1100g Attached cable:Approx.620g

ENVIRONMENTAL CHARACTERISTICS

Sensing Cell Ge Photodiode
Sensitivity Wave Length 0.8 to 1.8μm
Detection Temperature
Range
Low Temp. Range / High Temp. Range
Switch with operation panel
STB Function Built-in
Display Figure display Received light level : 3 digit display Red LED
Threshold value : 2 digit display Green LED
Operation
display light
Output [OP.L] : Orange LED
Stability [STB] :Green LED
Simulation input [SIMU] : Orange LED
Temperature
range display
High temperature range (Ht):Orange LED
Low temperature range (Lt):Orange LED
Received light level
display range
0.0 to 12.0 (0.1 step)
Operation Light Level
Set-up Range
1.0 to 9.0 (0.1 step)
Simulation Input ON : Short-circuit (Outflow current 5mA max)
OFF : Open-circuit
 
go to page top