FT101 series
 
FT101  
Free power supply voltage
Monitor output for transmitter is equipped
Withstand 200ºC without cooling
DIMENSIONS OUTPUT CIRCUIT PDF DXF
Specifications
Output specification
Models FT-L101
Light source Infrared LED
Light monitor Output Relay contact output 1C
Operation
Rating AC250V 2A (Resistance load)
Models FT-R101
Output mode Relay contact output 1C
  Rating AC250V 2A (Resistance load)
Operating mode Light-ON / Dark-ON (Switching)
Response time
20ms Max.
General specification
Range
Fiber unit Only fiber unit on FA51/52 on OHC
GT205AD 55cm 2.7m 22m
GT21AD 55cm 2.7m 22m
GT22AD 50cm 2.5m 20m
GT23AD 45cm 2.2m 18m
GT25AD 40cm 2.0m 16m
GT27AD 35cm 1.8m 14m
GT210AD 30cm 1.5m 12m
Fiber-optic unit
allowable bending radius
50mm
Power Supply AC100 to 240V, ±10% 50/60Hz
Power consumption Trns. Rcvr.: 2W Max.
Indicators Trns. Power: Greeen LED, Monitor: Red LED
Rcvr. Power: Greeen LED, Monitor: Red LED
Connection Terminal block type (screw: M3.5, width: 8.1mm)
Usage ambient temperature

Optical head, Fiber unit: -25 to +200ºC
Amp. unit: -25 to +55ºC (Non freezing)

Storage temperature range -40 to +70ºC (Non condensing)
Usage ambient humidity 35 to 85%RH (Non condensing)
Usage ambient illuminance 10,000 lx (incandescent lamp)
Fiber-optic unit
allowable bending radius
IP66
Resistance to vibration 10 to 55Hz, Doble oscillation 1.5mm X, Y, Z 3ways 2hours on each
Voltage endurance Input/Output - Case, Input - Output
AC2000V per minute
Insulating resistance 20MΩ Max. (at DC500VM)
Marerials Zinc dicast
Weight Trns.: 720g, Rcvr.: 720g