FT10A series
FT10A
Withstand 200ºC without cooling
5 point level indicator for sensitivity
Highly durable detector unit
Self check Function(safety function) built-in
Various hoods are available
DIMENSIONS OUTPUT CIRCUIT PDF DXF
Specifications
Output specification
Models FTL10A
Monitor output
(OPERATION)
Operation
Rating
Contact output MAX 5A 250V AC (Resistance load)
Other Matsushita: ST1-DC24V
Models FTR10A

FTR10AH

FTR10AC
Output mode Mini power relay Lead relay Solide state
Control Output ON-OFF control
Rating Transfer contact
MAX 5A 250V AC
(Resistance load)

Transfer contact
MAX 0.5A 48V DC
(Resistance load)

MAX 0.5A
250V AC DC
(Resistance load)

Response time 15ms Max. 5ms Max. 3ms Max.
SAFETY
ALARM output
Operation
Rating a contact
MAX 5A 250V AC (Resistance load)
MAX 0.5A 250V AC·DC
(Resistance load)
General specification
Range
Optical fiber unit / Length:
2m…40m Max.
5m…30m Max.
10m…20m Max.
Valid lens diameter 28mm DIA
Min. object resolution 28mm DIA
Power Supply AC100 to 220V +10%, -15% 50/60Hz
Power consumption Trns.: 10W Max., Rcvr.: 10W Max.
Connection Connector cable 2m (CVV 1.25mm2)
Usage ambient temperature Optical head, Fiber unit: -25 to +200ºC
Amp. unit: -25 to +55ºC (Non freezing)
Storage temperature range -40 to +70ºC (Non condensing)
Usage ambient humidity 35 to 85%RH (Non condensing)
Fiber-optic unit
allowable bending radius
50mm
Insulating resistance Power - Case: at DC500VM 20MΩ Max.
Output - Case: at DC500VM 20MΩ Max.
Power - Output: at DC500VM 20MΩ Max.
Voltage endurance Power - Case: AC1500V per minute
Output - Case: AC1500V per minute
Unless, Lead relay - Output: AC1000V per minute
Power - Output: AC1500V per minute
Unless, Lead relay - Output: AC1000V per minute
Resistance to vibration 10 to 55Hz, Doble oscillation 1.5mm X, Y, Z 3ways 2hours on each
Shock endurance 490m/s2 X, Y, Z 3ways 3times on each
Protective construction IP66
Weight
Optical head OHA: 680g
Air less hood F38A: 240g F38A-03: 430kg  
F38A-04: 550g F38A-05: 650kg  
Air purge hood F38PC-02: 240g F38PC-03: 300g  
  F38PC-04: 370g F38PC-05: 440g  
Fiber unit FG2: 600g FG3: 800g FG4: 1.0kg
  FG5: 1.3kg FG7: 1.8kg FG10: 2.4kg
Amp. unit
Trns.: 1.5kg
Rcvr.: 1.5kg
 