| Models |
DA-S100RTC |
DA-S200TC |
D-S100RP |
DA-S200P |
| Detection |
Background suppression |
| Range |
0.2~1m |
0.2~2m |
0.2~1m |
0.2~2m |
| Adjustable range |
0.4~1m |
0.4~2m |
0.4~1m |
0.4~2m |
| Power supply |
12 to 24VDC0%,
Ripple 10% Max. |
AC/DC24 to 240V,10%
50/60Hz |
| Current consumption |
45mA (Max.) |
2.5W (Max.) |
| Output mode |
NPN/PNP open collector
2 outputs
Rating: 100mA DC30VMax.
NPN: Sink current
PNP: Source current
|
Relay output 1a
Rating: 3A AC250V (Max.) Resistive
3A 30VDC (Max.) Resistive |
| Circuit protection |
Short circuit protection
built-in |
- |
| Operating mode |
Light-on/Dark-on
selectable |
| Timer |
On-delay/Off-delay
selectable |
| Delay time |
0 ~ 5s adjustable |
| Response time |
5ms Max. |
20ms Max. |
| Hysteresis |
10% Max. |
| Light source |
Red LED(650nm) |
Infrared LED(880nm) |
Red LED(650nm) |
Infrared LED(880nm) |
| Indicators |
Operation indicator:
Orange LED,
Stability: Green LED, Error: Red LED |
| Materials |
Acrylic |
Polycarbonate |
Acrylic |
Polycarbonate |
| Cable |
Flying lead 2m |
M8 connector |
| Weight (Max.) |
200g |