| Detection method | Through beam |
|---|---|
| Detecting distance | 2m |
| Detection object | Opaque dia.35mm or more |
| Number of beams | 5 |
| Detecting width | 100mm |
| Beam interval | 25mm |
| Power supply | 12-24VDC ±10% / Ripple 10% or less |
| Current consumption | 130mA or less |
| Output mode | Control output : Selectable between NPN output and PNP output with switch Rating : Sink current 50mA (30VDC) or less / Residual voltage: 2V or less |
| Operation mode | Light ON/Dark ON selectable (with switch) |
| Frequency switching feature | Provided (for up to 2 units) |
| Response time | Normal: Light reception: 35 ms or less Light blocking: 25 ms or less With frequency switching feature enabled: Light reception: 45 ms or less Light blocking: 28 ms or less |
| Job light input | Contact or non-contact input |
| Light source | Infrared LED (wavelength : 880nm) |
| Indicator | Transmitter: Power indicator (green LED) / Job indicator (green) Receiver :Received light intensity indicator (green / orange LED) / Light blocking indicator (orange LED) Job indicator (green) / Fault indicator (red LED) |
| Job indicator Fault indicator |
Continuous/flashing illumination selectable with the switch Flashing speed: FAST/SLOW selectable with the switch |
| Output short circuit protection | Provided |
| Automatic sensitivity compensation | Provided |
| Material | Case : Aluminum / caps at ends (mounting legs): PBT with glass fiber lens: Polycarbonate / switch cover: Polyester elastomer |
| Connection | Cable with M12 4 pin connector pigtail, 0.3m transmitter: gray / receiver: black |
| Weight | Transmitter: approx. 80g Receiver: approx. 95g |
| Accessory | Screwdriver for switch operation mounting bracket is not separately available. |
| Ambient light | 10,000lx or less |
|---|---|
| Ambient temperature | -10 - +55 ℃ (non-freezing) |
| Ambient humidity | 35-85%RH (non-condensing) |
| Vibration | 10 - 55Hz / 1.5mm double amplitude / 2 hours each in 3 directions |
| Shock | 500m/s2 / 2 times each in 3 directions |
| Protective structure | IP62 |
| Dielectric withstanding | 1,000VAC 50/60Hz for 1 minute |
| Insulation resistance | 500VDC, 20MΩ or higher. |