Detecting distance | Retro reflective : 2m or less Diffuse reflective : 700mm(White drawing paper 300mmx300mm) 400mm(18% reflectivity gray card A4 size) |
---|---|
Number of beams | 8 |
Detecting width | 225mm |
Power supply | 12-24VDC ±10% / Ripple 10% or less |
Current consumption | 92mA or less / DC12V 58mA or less / DC24V |
Output mode | Control output : NPN / PNP output selectable Rating : NPN output: Sink current 50mA (30VDC) or less residual voltage 2V or less PNP output: Source current 50mA (30VDC) or less, residual voltage 2V or less |
Operation mode | Normal open/Normal close selectable |
Job indicator | Input: Non-contact or contact input Operating voltage: NPN 2V or less/ PNP 8V or more |
Response time | 120ms or less |
Light source | Infrared LED (wave length: 640nm) |
Indicators | Initial sensitivity setting indicator (green LED/orange LED)/ Operating indicator(orange LED) Job indicator (green)/ Fault indicator(red LED) |
Job indicator Fault indicator |
Flashing |
Short circuit protection | Provided |
Material | Enclosure: Aluminum, End caps: PBT with glass fiber, Lens: Polycarbonate |
Wiring | Cable with M12 connector 0.3m (black) |
Auxiliary functions | Automatic initialization function/Automatic re-initialization function |
Weight | approx. 180g |
Accessories | Driver for switch operation, operation manual (mouning bracket and reflector are separately available.) |
Ambient light | 10,000lx or less |
---|---|
Ambient temperature | -10 - +55 ℃ (non-freezing) |
storage temperature | -25 - +70 ℃ (non-freezing or non-condensing) |
Ambient humidity | 35-85%RH (non-condensing) |
Vibration | 10 - 55Hz / 1.5mm double amplitude / 2 hours each in 3 directions |
Shock | 500m/s2 / 2 times each in 3 directions |
Protective structure | IP62 |
Dielectric withstanding | 1,000VAC 50/60Hz for 1 minute |
Insulation resistance | 500VDC, 20MΩ or higher. |