Power supply | 12 - 24VDC ±10% / Ripple 10% or less |
---|---|
Current consumption | 39 mA or less |
Output mode | Open collector output / Rating: Sink current 100 mA (30 VDC) or less / Residual voltage: 1 V or less |
Operation mode | Light ON/Dark ON selectable |
Timer | Off delay/disabled selectable Delay time: 40 ms fixed |
Response time | Light emission frequency channel 1: 600 μs or less Light emission frequency channel 2: 700 μs or less |
Light source(wavelength) | White LED |
Indicator | Operation indicator: orange LED / Stability (STB) indicator: green LED |
Display | LCD display with backlight |
Switch | 2 set buttons / Mode selector switch: RUN/SET |
Sensitivity setting | Full auto teaching / Auto teaching |
Sensitivity setting input | Set button input |
Sensitivity adjustment function | Provided (manual sensitivity adjustment) |
Functions | * Mutual Interference prevention feature * Short circuit protection feature |
Material | Polycarbonate |
Connection | M8 connector |
Weight | Cable type: approx. 80 g (including cables and mounting bracket); M8 connector type: approx.. 25g |
Accessory | Mounting bracket / Operation manual |
(*) Detection can start when more than 0.5 seconds has passed after power up. If the load and this sensor use different power sources, be sure to turn on the sensor first.
Ambient light | Incandescent lamp: 10,000 lx / Sunlight: 20,000 lx |
---|---|
Ambient temperature | 1-3 adjacent units in operation: -25 - +55 ℃ 4-10 adjacent units in operation: -25 - +50 ℃ 11-16 adjacent units in operation: -25 - +45 ℃ Storage: -40 - +70 ℃ (non-freezing) |
Ambient humidity | 35 - 85%RH (non-condensing) |
Protective structure | IP40 |
Vibration | 10 - 55 Hz / 1.5 mm double amplitude / 2 hours each in 3 direction |
Shock | 500 m/s2 / 3 times each in 3 directions |
Dielectric withstanding | 1000 VAC for 1 minute |
Insulation resistance | 500 DVC, 20MΩ or more |