F85RN-ILP

Specification

Power supply 12 to 24VDC Ripple 10% or less *
Power consumption 1000mW or less (40mA or less at 24V)
Control output PNP open collector output / Load current 100mA (30VDC, class2) or less / Residual voltage: 2V or less
NPN open collector output / Load current 100mA (30VDC, class2) or less / Residual voltage: 2V or less
Operation mode Light ON / Dark ON
Timer ON delay, OFF delay, ON/OFF delay, One-shot, Timer off
Delay timer : 1ms to 9999ms (set in millisecond)
Response time H-SP mode : 50 μs or less / Standard mode : 500 μs or less /
Long mode : 4ms or less / Super long mode : 32ms or less
Light source (wavelength) Four-element (ALGalnP) LED (660nm)
Indicator Operation indicator, Setting / Teaching indicator, Light ON/Dark ON indicator: orange LED
Display Received light level : 4 digits in red LED (high-speed mode (0 to 3800), standard/long/super long modes (0 to 9999))
Threshold : 4 digits in green LED (high-speed mode (0 to 3500), standard/long/super long modes (0 to 9700))
Sensitivity setting 2-point teaching / Max sensitivity teaching / Full auto teaching / Positioning teaching / Window mode teaching
Light source level adjustment Provided (auto / manual)
Mutual Interference prevention UP to 8 units (standard, long, and super long modes) / 0 unit (high speed)
Protection circuit Power reverse connection / Output short-circuit protection
Material Polycarbonate
Wiring Cable with M12 connector
(cable length: 0.15m) 0.2mm2×4-core, o.d. Ø4.2mm)
Weight Approx. 35g
Accessory Instruction manual

* UL: Class 2 power source

Environmental specification

Ambient light Illumination on light receiving surface: 3,500 lx or less (incandescent lamp)
Ambient temperature 1 to 5 adjacent units in operation : -25 to +55°C
6 or more adjacent units in operation : -25 to +50°C *1
Storage: -40 to +70°C (no freezing or condensation)
Ambient humidity 35 to 85% RH (no condensation)
Protective structure IP40
Vibration 10 to 55 Hz / 1.5 mm double amplitude / 2 hours each in X, Y, and Z directions
Shock 500 m/s2 / 3 times each in X, Y and Z directions
Dielectric withstanding 1000 VAC for 1 minute
Insulation resistance 500 VDC mega, 20 MΩ or more

*1 UL: Maximum ambient temperature: +50°C for single use, +40°C for two or more units connected installation.