| Power supply | 12 - 24VDC ±10% / Ripple 10% or less |
|---|---|
| Power consumption | 830 mW or less (32 mA or less at 24 V) |
| Output mode | PNP open collector output Rating: Source current 100 mA (30 VDC) or less Residual voltage: 2 V or less |
| Operation mode | Light ON/Dark ON selectable with sliding switch |
| Timer | Off delay/disabled selectable with sliding switch |
| Response time (*1) | Delay time: 45 ms fixed |
| Light source (wavelength) | Red LED (680 nm) |
| Indicator | Operation indicator: orange LED / Mode indicator: yellow LED / Teaching indicator: green LED |
| Display | Received light level: 4 digits in orange LED (0 - 8000) |
| Switch | Output mode selector switch x 1 / Timer selector switch: 1 / Teaching and sensitivity adjustment push + 4-direction button switch x 1 |
| Sensitivity setting | Full auto teaching / Auto teaching |
| Sensitivity adjustment function | Provided (manual sensitivity adjustment) |
| Protection circuit | Reverse connection protection / Short circuit protection |
| Material | Polycarbonate |
| Wiring | 2m attached cable (Outer dimension: dia.3.7mm) 0.2sq. 3 cores |
| Weight | Approx. 60 g (including 2m cable and mounting bracket) |
| Accessory | Mounting bracket / Operation manual |
(*1) For initial setting and checking, output operation is disabled for about 1.5 seconds after power-up.
The factory setting is long-distance mode.
| Ambient light | Illumination on light receiving surface: 3,500 lx (incandescent lamp) |
|---|---|
| Ambient | 1-5 adjacent units in operation: -25 - +55℃ / Over 6 adjacent units in operation: -25 - +50℃ Storage: -40 - +70℃ (non-freezing) |
| Ambient humidity | 35 - 85%RH (non-condensing) |
| Protective structure | IP40 |
| Vibration | 10 - 55 Hz / 1.5 mm double amplitude / 2 hours each in 3 directions |
| Shock | 500 m/s2 / 3 times each in 3 directions |
| Dielectric withstanding | 1000 VAC for 1 minute |
| Insulation resistance | 500 VDC, 20MΩ or more |