Power supply | 12 - 24VDC ± 10% / Ripple 10% or less |
---|---|
Current consumption | 50 mA or less |
Output mode | Control output (*) : Open collector output / Rating: Source current 100 mA (30 VDC) or less / Residual voltage: 2 V or less |
Operation mode | Light ON/Dark ON selectable |
Timer | Off delay/disabled selectable Delay time: 40 ms fixed |
Response time | Frequency channel 1: 600 μs or less Frequency channel 2: 700 μs or less |
Light source (wavelength) | White LED |
Indicator | Operation indicator: orange LED / Stability indicator: green LED |
Display | LCD display with backlight |
Switch | 2 set buttons / Mode selector switch: RUN/SET |
Sensitivity setting | Full auto teaching / Auto teaching |
Sensitivity setting input | Set button input |
Sensitivity adjustment function | Provided (manual sensitivity adjustment) |
Functions | * Mutual Interference prevention feature * Short circuit protection feature |
Material | Polycarbonate |
Connection between amplifier units | Connector (for power supply) Input-output connection Connector: (using a dedicated connector cable *1) |
Maximum number of attachments and detachments of connector | 50 or less |
Weight | Approx. 20 g (main unit only) |
Accessory | Instruction manual, Terminal cap |
* When you connect more than one sensor, you can supply the electric power to any of them. However, the output current is different, depending on which sensor is supplied with the power.
When the power supply is for the center part, control output is 50 mA or less (F70A type: 70 mA or less); stability output is 20 mA or less
When the power supply is for either end, control output is 20 mA or less (F70A type: 40 mA or less); stability output is 20 mA or less
Detection can start when more than 0.5 seconds has passed after power-up. If the load and this sensor use different power sources, be sure to turn on the sensor first.
*1 Please use a connector cable dedicated for input-output connection which is sold separately.
Power/output connector cable
Model F7K-4 (4 core; colors of lead wires: brown, blue, black, orange)
Model F7K-3 (3 core; colors of lead wires: brown, blue, black)
Connector cable dedicated for output
Model F7K-2 (2 core; colors of lead wires: black, orange)
Model F7K-1 (1 core; color of lead wire: black)
Ambient light | Incandescent lamp: 10,000 lx / Sunlight: 20,000 lx |
---|---|
Ambient temperature | 1-3 adjacent units in operation: -25 ‐ +55℃ 4-10 adjacent units in operation: -25 ‐ +50℃ 11-16 adjacent units in operation: -25 ‐ +45℃ Storage: -40 ‐ +70℃ (non-freezing) |
Ambient humidity | 35 ‐ 85%RH (non-condensing) |
Protective structure | IP40 |
Vibration | 10 ‐ 55Hz / 1.5 mm double amplitude / 2 hours each in 3 direction |
Shock | 500 m/s2 / 3 times each in 3 directions |
Dielectric withstanding | 1000 VAC for 1 minute |
Insulation resistance | 500 VDC, 20MΩ or more |