Power supply | 12 - 24VDC ± 10% / Ripple 10% or less |
---|---|
Current consumption | 39 mA or less |
Output mode | Control output (*) : Open collector output / Rating: Sink current 100 mA (30 VDC) or less / Residual voltage: 1 V or less Stability output (*) : Open collector output / Rating: sink current 50 mA (30 VDC) or less / Residual voltage: 1 V or less |
Operation mode | Light ON/Dark ON selectable |
Timer | On delay/off delay/on off delay/disabled selectable Delay time: selectable between 10, 20, 40, 60, 80, 100 and 120ms / Default: 40ms |
Response time | Frequency channel 1: 500 μs or less Frequency channel 2: 600 μs or less |
Light source (wavelength) | Red LED (680nm) |
Indicator | Operation indicator: orange LED / Stability indicator: green LED |
Display | LCD display with backlight |
Switch | 2 set buttons / Mode selector switch: RUN/SET |
Sensitivity setting | Full auto teaching / Auto teaching |
Sensitivity setting input | Set button input |
Sensitivity adjustment function | Provided (manual sensitivity adjustment) |
Functions | * Sensor function: AUTO/TEACH/LOCK * Auxiliary function: S for manual adjustment of sensitivity and activation level H for manual hysteresis setting V for gap indication and absolute value indication modes * Mutual Interference prevention feature * Self-diagnosis feature * Short circuit protection feature |
Material | Polycarbonate |
Connection between amplifier units | Connector (for power supply) Input-output connection Connector: (using a dedicated connector cable *1) |
Maximum number of attachments and detachments of connector | 50 or less |
Weight | Approx. 20 g (main unit only) |
Accessory | Instruction manual, Terminal cap |
* When you connect more than one sensor, you can supply the electric power to any of them. However, the output current is different, depending on which sensor is supplied with the power.
When the power supply is for the center part, control output is 50 mA or less (F70 type: 70 mA or less); stability output is 20 mA or less
When the power supply is for either end, control output is 20 mA or less (F70 type: 40 mA or less); stability output is 20 mA or less
Detection can start when more than 0.5 seconds has passed after power-up. If the load and this sensor use different power sources, be sure to turn on the sensor first.
*1 Please use a connector cable dedicated for input-output connection which is sold separately.
Power/output connector cable
Model F7K-4 (4 core; colors of lead wires: brown, blue, black, orange)
Model F7K-3 (3 core; colors of lead wires: brown, blue, black)
Connector cable dedicated for output
Model F7K-2 (2 core; colors of lead wires: black, orange)
Model F7K-1 (1 core; color of lead wire: black)
Ambient light | Incandescent lamp: 10,000 lx / Sunlight: 20,000 lx |
---|---|
Ambient temperature | 1-3 adjacent units in operation: -25 ‐ +55℃ 4-10 adjacent units in operation: -25 ‐ +50℃ 11-16 adjacent units in operation: -25 ‐ +45℃ Storage: -40 ‐ +70℃ (non-freezing) |
Ambient humidity | 35 ‐ 85%RH (non-condensing) |
Protective structure | IP40 |
Vibration | 10 ‐ 55Hz / 1.5 mm double amplitude / 2 hours each in 3 direction |
Shock | 500 m/s2 / 3 times each in 3 directions |
Dielectric withstanding | 1000 VAC for 1 minute |