Detection method | Dioptric |
---|---|
Detection object | Liquid *1 |
Repeatability | 1 mm or less (for water) |
Withstand pressure | - 0.1 MPa - +0.5 MPa |
Ambient temperature *2 | - 40 - +70 ℃ (FL type) / - 40 - +100 ℃ (FLH type) |
Allowable bending radius | R40 mm (50 mm from tip unbendable) |
Fiber optic cable length | See “Dimensions” |
Material | Covering : PFA Fiber optic cable : Plastic |
Mass | 80g or less |
Applicable amplifier | F85RN、F80R、F70AR、F70R |
*1 : Chromatic or achromatic transparent material (be sure to test with a sample in advance for liquid with high
viscosity or turbidity).
*2 : No condensation in PFA (Fluoropolymer) tube.