| Detection method | Identification of color ratios through R/G/B light receptive elements | 
|---|---|
| Detection distance | Depends on the use environment | 
| Standard detection target | Light source emitting visible lights | 
| Power Supply | 12 to 24 V DC ±10%, Ripple 10% or less | 
| Current consumption | 1000mW or less (40mA or less) at 24V DC | 
| Reference color registration | Via teaching: 1 color (for Mode 1)  Via teaching: 3 colors (for Mode 3)  | 
                        
| Reference color setting | 1-point teaching / 2-point teaching | 
| External input/output | 1 input, 1 output (for Mode 1),  3 outputs (for Mode 3)  | 
                        
| External teaching input | No-voltage input (With or without contact point) (only for Mode 1) | 
| Output mode | NPN/PNP open collector output (operation switch)  Load current: 50mA (30V DC) or less, Residual voltage: 2V or less  | 
                        
| Operation mode | Switch “Match ON”/“Match OFF”with the reference color | 
| Timer | ON Delay / OFF Delay / One Shot / No timer Delay time: 1 to 999 ms (setting available in an interval of 1ms)  | 
                        
| Response time | Auto (10 ms or less at maximum, depending on the illumination  conditions of the workpiece) / 50 ms or less / 100 ms or less / 250 ms or less / 500 ms or less (selectable)  | 
                        
| Indicators | Operation indicator, Setting indicator,Match ON (NO) and Match OFF (NC) Indicator: Orange LED | 
| Display | Tolerance value display: Green LED, 4-digit/  Maximum difference display of color ratios: Red LED, 4-digit  | 
                        
| Protection circuit | Protection against power reversed connection and output short-circuit | 
| Material | Polycarbonate | 
| Connection method | Attached cable type (φ4.2 mm2 o.d.) 0.2 mm2 x 5-core, 2m | 
| Accessories | Instruction manual | 
| Ambient temperature | -25 to +55℃ at storage (no freezing) | 
|---|---|
| Ambient humidity | 30 to 85 % RH (no condensation) | 
| Protection structure | IP40 | 
| Anti-vibration | 10 to 55 Hz, double amplitude 1.5 ㎜, X, Y, Z directions, 2 hour each | 
| Shock | 500m/s2, 3 times each in X, Y and Z directions | 
| Dielectric withstand voltage | 1000V AC for 1 minute | 
| Insulation resistance | 20MΩ or more with 500V DC Megger |