| Detection method | Through beam | 
|---|---|
| Detecting distance | 500 mm | 
| Detection object | dia.3mm (or more) Opaque | 
| Power supply | 24VDC±10% / Ripple 10% or less | 
| Current consumption | Transmitter : 15mA or less Receiver : 22mA or less  | 
                        
| Output mode | NPN open collector Rating: sink current 80mA (30 VDC) or less  | 
                        
| Operation mode | (See the Type table in the previous page) | 
| Response time | 0.5ms or less | 
| Light source | Red LED | 
| Indicator | Transmitter: - Receiver: Operation indicator (red LED), Stability indicator (green LED)  | 
                        
| Sensitivity adjustment * | in-line volume | 
| Material | Case : Liquid crystalline polyester (filler: polypropylene) Lens : PMMA  | 
                        
| Connection | Attached cable 2m Transmitter:0.15mm2×2 core (Gray), dia φ2.5mm Receiver:0.15mm2×3core (Black), dia φ2.7mm  | 
                        
| Weight | Transmitter : Approx. 30g Receiver : Approx. 40g  | 
                        
| Notes | * The distance between the sensor and the in-line volume for sensitivity adjustment is fixed to 300mm. | 
| Accessory | Instruction manual, screws(M12×10mm), nuts, washers and a screwdriver for adjustment (for models which model number ends with "V") | 
| Ambient light | 3,000 lx or less | 
|---|---|
| Ambient temperature | -25 - +55 ℃ (non-freezing) | 
| Ambient humidity | 35-85%RH (non-condensing) | 
| Protective structure | IP64 | 
| Vibration | 10 - 55 Hz / 1.5 mm double amplitude / 2 hours each in 3 direction | 
| Sock | 500m/S2 3 times each in 3 directions | 
| Dielectric withstanding | 1000VAC 1minuts | 
| Insulation resistance | DC500V Megger 20MΩ or higher |