| Detection method | Convergent reflective | 
|---|---|
| Detecting distance | 1~40 mm ( 50 x 50 mm white drawing paper) | 
| Detection object | Opaque, translucent, transparent | 
| Power supply | 12-24V DC ±10% / Ripple 10% or less | 
| Current consumption | 22mA or less | 
| Output mode | Control output : NPN open collector output Rating: sink current 100mA (30 VDC) or less Stability output : NPN open collector output Rating: sink current 50mA (30 VDC) or less  | 
                        
| Operation mode | Light-ON/Dark-ON selectable (with switch) | 
| Response time | 0.35ms or less | 
| Hysteresis | 10% or less | 
| Light source (light wavelength) | Infrared LED (900nm) | 
| Indicator | Operation indicator (red LED) Stability indicator (green LED)  | 
                        
| Volume | SENS: Sensitivity adjusment (on receiver for through-beam type) | 
| Switch | Light-ON/Dark-ON selector switch provided | 
| Short circuit protection | Provided (for control output only) | 
| Material | Case : Polyarylate Lens : Polycarbonate  | 
                        
| Connection | Cable type (outer diameter: 3mm; length 2m) 0.15mm2 x 4 cores (black)  | 
                        
| Weight | Approx. 50g | 
| Accessories | Mounting bracket, operation manual provided | 
| Ambient light | 5,000 lx or less | 
|---|---|
| Ambient temperature | –25 - +55°C (non-freezing) | 
| Ambient humidity | 35-85%RH (non-condensing) | 
| Protective structure | IP67 | 
| Vibration | 10-55 Hz / 1.5 mm double amplitude / 2 hours each in 3 direction | 
| Shock | 500 m/s2 / 3 times each in 3 directions | 
| Dielectric strength | 1,000 VAC for 1 minute | 
| Insulation resistance | 500 VDC, 20 MΩ or higher |