| Detection method | Spectroscopy measurement by red/green/blue LEDs |
|---|---|
| Detecting distance | 12 to 24 VDC ±10% Ripple: 10 % or less. |
| Power supply | 1.6 W or less. |
| Response time | Normal (NML) mode: 1 ms or less. Average value (AVE) mode: 5 ms or less. |
| Output mode | NPN open collector output Sink current 100 mA (30 VDC) or less. |
| External input | No voltage input: input duration 60 ms or more. |
| Differentiation factor | COL (color component)/C + Y (color component and brightness) |
| Teaching | Auto (AUT)/Manual (MAN)/Mix (MIX) |
| Timer function | Time disabled (NON)/Off delay OFD) approx. 50 ms |
| Light source | Red, green, blue LEDs (RGB composition) |
| Light-sensitive element | Photodiode |
| Indicator | Power indicator (RUN): Yellow LED Illuminated while power is supplied, flashes during teaching Operation indicator (OP.): Orange LED Illuminated when output is activated, flashes during mix teaching Stability indicator (STB.): Green LED Illuminated for stable detection, flashes during auto teaching Error indicator (ERR): Red LED Illuminated to indicate teaching error, flashes to indicate sensor fail |
| Protective feature | Output short circuit protection, power supply protection against reverse connection |
| Protective structure | IP 65 (with fiber optic cable attached) |
| Case material | Case: heat-resistant ABS / Cover: polycarbonate |
| Connection | Attached cable (Outer dimension: dia.4.5 mm) 0.2 mm2 x 4 cores, 2 m |
| Weight | Approx. 100 g |
| Accessory | 1 mounting bracket, 1 screwdriver for setting, operation manual |
| Ambient temperature | -10 to +55 ℃ (non-freezing) |
|---|---|
| Ambient humidity | 35 to 85%RH (non-condensing) |
| Vibration | 10 to 55 Hz / 1.5 mm double amplitude / 2 hours each in 3 direction |
| Shock | 500 m/s2 / 3 times each in 3 directions |
| Dielectric withstanding | 1,000 VAC for 1 minute |
| Insulation resistance | 500 VDC, 20 MΩ or more |