Detection method | Spectroscopy measurement by red/green/blue LEDs |
---|---|
Detecting distance | 12 to 24 VDC ±10% Ripple: 10 % or less. |
Power supply | 1.6 W or less. |
Response time | Normal (NML) mode: 1 ms or less. Average value (AVE) mode: 5 ms or less. |
Output mode | PNP open collector output Source current 100 mA (30 VDC) or less. |
External input | No voltage input: input duration 60 ms or more. |
Differentiation factor | COL (color component)/C + Y (color component and brightness) |
Teaching | Auto (AUT)/Manual (MAN)/Mix (MIX) |
Timer function | Time disabled (NON)/Off delay OFD) approx. 50 ms |
Light source | Red, green, blue LEDs (RGB composition) |
Light-sensitive element | Photodiode |
Indicator | Power indicator (RUN): Yellow LED Illuminated while power is supplied, flashes during teaching Operation indicator (OP.): Orange LED Illuminated when output is activated, flashes during mix teaching Stability indicator (STB.): Green LED Illuminated for stable detection, flashes during auto teaching Error indicator (ERR): Red LED Illuminated to indicate teaching error, flashes to indicate sensor fail |
Protective feature | Output short circuit protection, power supply protection against reverse connection |
Protective structure | IP 65 (with fiber optic cable attached) |
Case material | Case: heat-resistant ABS / Cover: polycarbonate |
Connection | Attached cable (Outer dimension: dia.4.5 mm) 0.2 mm2 x 4 cores, 2 m |
Weight | Approx. 100 g |
Accessory | 1 mounting bracket, 1 screwdriver for setting, operation manual |
Ambient temperature | -10 to +55 ℃ (non-freezing) |
---|---|
Ambient humidity | 35 to 85%RH (non-condensing) |
Vibration | 10 to 55 Hz / 1.5 mm double amplitude / 2 hours each in 3 direction |
Shock | 500 m/s2 / 3 times each in 3 directions |
Dielectric withstanding | 1,000 VAC for 1 minute |
Insulation resistance | 500 VDC, 20 MΩ or more |