Detection method | Polarized retroreflective |
---|---|
Detecting distance | 0.03-3m (with K-7 reflector) |
Detection object | Mirror-like opaque |
Power supply | 24-240V AC/DC ±10% 50/60Hz |
Power consumption | 2 W or less |
Output mode | Relay output 1a / Rating: 2 A (250 VAC) or less resistance load |
Operation mode | Light ON/Dark ON selectable. (with switch) |
Response time | 5ms or less (*) |
Operating angle | 30° (at reflector) |
Light source (wavelength) | Red LED |
Indicator | Transmitter P.L: power indicator (red LED) Receiver OP.L: operation indicator (red LED) STB: stability indicator (green LED) |
Switch (SW) | Light ON/Dark ON selector switch (integrated on bottom of sensor unit) |
Material | Case : Acrylic |
Connection | Terminal block (with M3.5 screws) |
Weight | Approx. 250g |
Notes | (*) While the response time is fast, use at a switching frequency of 30/min or less is recommended for the life of the relay. |
Accessory | Operation manual, Mounting bracket, reflector model K-7 |
(*) While the response time is fast, use at a switching frequency of 30/min or less is recommended for the life of the relay.
Ambient light | 10,000 lx or less |
---|---|
Ambient temperature | -25 - +55 ℃ (non-freezing) |
Ambient humidity | 35-85%RH (non-condensing) |
Protective structure | IP66 |
Vibration | 10-55 Hz / 1.5 mm double amplitude / 2 hours each in 3 directions |
Dielectric withstanding | 1,500 VAC for 1 minute |
Insulation resistance | 500 VDC, 100 MΩ or higher |