| Detection method | Diffuse reflective |
|---|---|
| Detecting distance | 700mm (200-mm square white drawing paper) |
| Detection object | Translucent opaque |
| Power supply | 24-240V AC/DC ±10% 50/60Hz |
| Power consumption | 2 W or less |
| Output mode | Relay output 1a / Rating: 2 A (250 VAC) or less resistance load |
| Operation mode | Light ON/Dark ON selectable. (with switch) |
| Response time | 5ms or less (*) |
| Hysterisis | 10% or less |
| Light source (wavelength) | Infrared LED |
| Indicator | OP.L: operation indicator (red LED) STB: stability indicator (green LED) |
| Volume (VR) | Sensitivity adjustment (at receiver) |
| Switch (SW) | Light ON/Dark ON selector switch (integrated on bottom of sensor unit) |
| Material | Case : Acrylic |
| Connection | Terminal block (with M3.5 screws) |
| Weight | Approx. 250g |
| Notes | (*) While the response time is fast, use at a switching frequency of 30/min or less is recommended for the life of the relay. |
| Accessory | Operation manual, Mounting bracket |
| Ambient light | 10,000 lx or less |
|---|---|
| Ambient temperature | -25 - +55 ℃ (non-freezing) |
| Ambient humidity | 35-85%RH (non-condensing) |
| Protective structure | IP66 |
| Vibration | 10-55 Hz / 1.5 mm double amplitude / 2 hours each in 3 directions |
| Dielectric withstanding | 1,500 VAC for 1 minute |
| Insulation resistance | 500 VDC, 100 MΩ or higher |