Detection method | Through beam |
---|---|
Detecting distance | 10m |
Detection object | Opaque object of dia.16 mm minobject of |
Power supply | 24-240V AC/DC ±10% 50/60Hz |
Power consumption | Transmitter/Receiver 2 W or less |
Output mode | Relay output 1a / Rating: 2 A (250 VAC) or less resistance load |
Operation mode | * Light ON/Dark ON selectable * Timer function selectable Selectable between on delay, off delay, one shot and timer disabled (with switch) Delay time: 0.1-1 s, 1-10 s |
Response time | 5ms or less (*) |
Operating angle | 5% (at receiver) |
Light source (wavelength) | Red LED |
Indicator | Transmitter P.L: power indicator (red LED) Receiver OP.L: operation indicator (red LED) STB: stability indicator (green LED) |
Volume (VR) | Delay time adjustment (at receiver) |
Switch (SW) | FUNCTION.SW provided (selects between functions) OND.: on delay △: Light ON ▲: Dark ON OFD.: off delay △: Light ON ▲: Dark ON OST.: one shot △: Light ON ▲: Dark ON NORM: timer disabled △: Light ON ▲: Dark ON (With rotary switch: integrated on bottom of sensor unit) Delay time range selector switch provided 0.1-1 s: variable between 0.1 and 1 second with TIME VR 1-10 s: variable between 1 and 10 sec |
Material | Case : Acrylic |
Connection | Terminal block (with M3.5 screws) |
Weight | Transmitter/Reflector Approx. 250 g |
Notes | (*) While the response time is fast, use at a switching frequency of 30/min or less is recommended for the life of the relay. |
Accessory | Operation manual, Mounting bracket |
Ambient light | 10,000 lx or less |
---|---|
Ambient temperature | -25 - +55 ℃ (non-freezing) |
Ambient humidity | 35-85%RH (non-condensing) |
Protective structure | IP66 |
Vibration | 10-55 Hz / 1.5 mm double amplitude / 2 hours each in 3 directions |
Dielectric withstanding | 1,500 VAC for 1 minute |
Insulation resistance | 500 VDC, 100 MΩ or higher |