| Detection method | Retroreflective |
|---|---|
| Detecting distance | 0.1-1m (with K-MT4 reflector) |
| Power supply | 12-24V DC ±10% / Ripple 10% or less |
| Current consumption | 25mA or less |
| Output mode | Control output : NPN open collector Sink current 100 mA (30 VDC) or less Rating : Residual voltage: 1 V or less Stability output : NPN open collector Sink current 50 mA (30 VDC) or less Rating :Residual voltage: 1 V or less |
| Operation mode | Light ON/Dark ON selectable |
| Response time | 1ms or less |
| Light source | Red LED (700 nm) |
| Indicator | Operation indicator (orange LED) Stability indicator (green LED) |
| Setting button | For sensitivity setting and Light ON/Dark ON selection *1 |
| Short circuit protection | Provided |
| Material | Sensor : Lens: acrylic / Case: polycarbonate Reflector : Mirror: acrylic / Base: heat resistant ABS |
| Connection | Attached cable (outer dimension: dia. 4.2 mm) 0.2 mm2 4 core 2 m length |
| Weight | Body: Approx.60 g / Reflector: Approx.15 g |
Special reflector (K-MT4), operation manual, explanation sticker, (Note) mounting bracket separately available
| Ambient light | 5,000 lx max. |
|---|---|
| Ambient temperature | -25 - +55 ℃ (non-freezing) |
| Ambient humidity | 35-85%RH (non-condensing) |
| Protective structure | IP 67 |
| Vibration | 10-55 Hz / 1.5 mm double amplitude / 2 hours each in 3 direction |
| Shock | 500 m/s2 / 3 times each in 3 directions |
| Dielectric withstanding | 1,000 VAC for 1 minute |
| Insulation resistance | 500 VDC, 20 MΩ or higher |