| Detection method | Reflective | 
|---|---|
| Detecting distance | 0.1 - 3m | 
| Standard detecting object | 300×900 mm white pape | 
| No. of optical zones | 3 (w/o area setting function) | 
| Power supply | 12-24VDC ±10% Ripple 10% or less | 
| Power consumption | 1.5W or less | 
| Output mode | PhotoMOS output (short circuit protection) Load current 50mA(30VDC) or less Residual voltage: 2V or less  | 
                        
| Operation mode | Light ON | 
| Anti Interference | Provided (when connected to Master/Slave : up to 4 units) | 
| Response time | ON : 0.1s OFF : 0.3s or less | 
| Light source (wavelength) | Infrared LED (850nm) | 
| Indicator (3 color LED) | Operation indicator : orange LED At Master w/ detection ON : orange LED lit ; detection OFF : blue LED lit At Slave w/ detection ON : orange LED lit ; detection OFF : green LED lit  | 
                        
| Volume (VR) | Distance adjuster (1 to 3m) | 
| Additional functions | Power reverse connection protection, output short-circuit protection | 
| Material | Case : Heat resistant ABS Front cover : Polycarbonate  | 
                        
| Connection | Attached cable(dia.4.8mm) 0.2mm2, 6 cores, 5m (black)  | 
                        
| Weight | Approx. 170g | 
| Accessory | Operation manual | 
| Ambient light | 20000 l x or less | 
|---|---|
| Ambient temperature | -20 - + 55 ℃ Storage : -40 - +70 ℃(non-freezing) | 
| Ambient humidity | 35-85%RH(non-condensing) | 
| Protective rating | IP40 | 
| Vivration resistance | 10 - 55Hz / 1.5 double amplitude / 2 hours each in 3 directions | 
| Dielectric withstanding | 1000 VAC for 1 minute | 
| Insulation resistance | 500V DC, 20MΩ or highter | 
| Shock resistance | 500 m/s2 / 3 times each in 3 directions |