| Detecting distance | 0.5 to 7.5m (*1) |
|---|---|
| Standard detecting object | 700×700mm white drawing paper |
| Power supply | 12 to 24V DC ±10% / Ripple 10% or less |
| Power consumption | 2.3W or less |
| Analog output | Current output: 4 - 20mA (allowable resistive load: 250 Ω or less) Resolution: ±5%F.S. or less (*2) Linearity: 10%F.S. or less Response frequency: Approx. 20Hz |
| Comparator output | Output mode: NPN open collector Sink current: 50 mA (30 VDC) or less / Residual voltage: 2 V or less Response frequency: Approx. 20Hz Mode switching: Light ON/Dark ON selectable Load short circuit protection: Provided |
| Anti Interference | Provided(Master/slave setting) |
| Light source (wavelength) | Infrared LED (870nm) |
| Switch (SW) | Pushbutton switch×3 |
| Teaching method | Auto teaching (for comparator output only) |
| Teaching mode | 1-point normal teaching, 2-point normal teaching, 1-point zone teaching |
| Material | case: Aluminum (alumite treatment) Front/back panel: ABS Lens: Polycarbonate Lens front cover: Polycarbonate |
| Connection | 6-pin waterproof plastic connector |
| Weight | Approx. 200 g |
| Accessory | Cable with connector (*3), 250-Ω resistor for current-voltage conversion, operation manual |
*1 繝サNote that any object with high reflectance at a distance of 40 - 80 m may cause faulty operation. 繝サThe comparator output is designed for a distance of 0.5 - 7 m. *2 Output of higher resolution may be available by averaging or integration. *3 0.2 mm^2テ
| Ambient light | 5000 lx max. (on light receiving surface) |
|---|---|
| Ambient temperature | -10 to +55 ℃ (non-freezing) |
| Ambient humidity | 35 to 85%RH (non-condensing) |
| Protective structure | IP65 |
| Vibration | 10 to 55 Hz / 1.5 mm double amplitude / 2 hours each in 3 directions |
| Shock | 500 m/s2 / 3 times each in 3 directions |
| Dielectric withstanding | 1,000 VAC for 1 minute |
| Insulation resistance | 500 VDC, 20 MΩ or higher |