| Detection method | Through beam | 
|---|---|
| Detecting distance | 2m | 
| Detection object | Opaque dia.35mm or more | 
| Number of beams | 13 | 
| Detecting width | 300mm | 
| Beam interval | 25mm | 
| Power supply | 12-24VDC ±10% / Ripple 10% or less | 
| Current consumption | 150mA or less | 
| Output mode | Control output : Selectable between NPN output and PNP output with switch Rating : Sink current 50mA (30VDC) or less / Residual voltage: 2V or less | 
| Operation mode | Light ON/Dark ON selectable (with switch) | 
| Frequency switching feature | Provided (for up to 2 units) | 
| Response time | Normal: Light reception: 70 ms or less Light blocking: 42 ms or less With frequency switching feature enabled: Light reception: 88 ms or less Light blocking: 54 ms or less | 
| Job light input | Contact or non-contact input | 
| Light source | Infrared LED (wavelength : 880nm) | 
| Indicator | Transmitter: Power indicator (green LED) / Job indicator (green) Receiver :Received light intensity indicator (green / orange LED) / Light blocking indicator (orange LED) Job indicator (green) / Fault indicator (red LED) | 
| Job indicator Fault indicator | Continuous/flashing illumination selectable with the switch Flashing speed: FAST/SLOW selectable with the switch | 
| Output short circuit protection | Provided | 
| Automatic sensitivity compensation | Provided | 
| Material | Case : Aluminum / caps at ends (mounting legs): PBT with glass fiber lens: Polycarbonate / switch cover: Polyester elastomer | 
| Connection | Cable with M12 4 pin connector pigtail, 0.3m transmitter: gray / receiver: black | 
| Weight | Transmitter: approx. 170g Receiver: approx. 180g | 
| Accessory | Screwdriver for switch operation mounting bracket is not separately available. | 
| Ambient light | 10,000lx or less | 
|---|---|
| Ambient temperature | -10 - +55 ℃ (non-freezing) | 
| Ambient humidity | 35-85%RH (non-condensing) | 
| Vibration | 10 - 55Hz / 1.5mm double amplitude / 2 hours each in 3 directions | 
| Shock | 500m/s2 / 2 times each in 3 directions | 
| Protective structure | IP62 | 
| Dielectric withstanding | 1,000VAC 50/60Hz for 1 minute | 
| Insulation resistance | 500VDC, 20MΩ or higher. |