Output type | Bestact relay output/Photo-MOS relay output |
---|---|
Control output | ON-OFF output Operation mode: Light ON (output activated when light received) Bestact relay output: Rating: 220VAC 0.5A/110VDC 0.3A or less (Inductive load) Response time: 6ms or less Photo-MOS relay output: Rating: 250VAC/DC 0.1A or less (Resistive load) Response time: 4ms or less |
Stability output | Operation mode: After seven consecutive runs with less margin for the threshold ligh intensity Output mode: Relay output: 1a 250VAC 5A (Resistive Load) Photo-MOS Relay Output: 1a 250VAC/DC 0.1A or less (Resistance Load) |
Current output | 4m-20mA (Allowable resistive load: 0-500Ω) Response time 4ms F.S. or less |
Valid lens diameter | dia.28mm(OHA, OHAN, OHAN10) |
Power Supply | 100-240VAC +10%, -15% 50/60Hz |
Power consumption | 6W or less |
Connection | Cable with connector (VCF 0.75mm2 x 16 cores 2m, gray) |
Ambient temperature | Optical head, Fiber unit: -25 ℃ to 200 ℃ Amplifier: -25 ℃ to 50 ℃(Non-freezing) |
Storage temperature | -40 ℃ to 70 ℃(Non-condensing) |
Ambient humidity | 35 to 85%RH (Non-condensing) |
Fiber optic unit allowable bending radius | 50mm |
Inslation resistance | Between power supply and case: 500 VDC, 20 MΩ or higher Between control/stability output and case: 500 VDC, 20 MΩ or higher Between power supply and control/stability output: 500 VDC, 20 MΩ or higher Between case and 4-20mA current output: 500 VDC, 20MΩ or higher Between power supply and 4-20mA current output: 500 VDC, 20MΩ or higher Between case and simulation input: 500 VDC, 20MΩ or higher Between |
Dielectric withstanding | Between power supply and case: 1500 VDC for 1 minute Between control/stability output and case: 1500 VDC for 1 minute (10mA) Between power supply and control/stability output: 1500 VDC for 1 minute (10mA) Between case and 4-20mA current output: 500 VDC for 1 minute (20mA) Between power supply and 4-20mA current output: 500 VDC for 1 minute (20mA) Between case and simulation input: 500 VDC for 1 minute |
Vibration | 10-55 Hz / 1.5 mm double amplitude / 2houtr each in 3 direction |
Shock | 500 m/s2 / 3 times each in 3 directions |
Protective structure | IP64 |
Weight | Optical head: Standard view type (OHA): Approx. 680g Wide view type (OHW1/OHW2): Approx. 1300g Narrow view type (OHAN) :Approx. 840g Narrow view type (OHAN10):Approx. 860g Airless hood: F38A : Approx. 240g F38A-04: Approx. 550g F38A-02: Approx. 330g F38A-05: Approx. 650g F38A-03: Approx. 430g F38W : Approx. 600g Air purge hood: F38PC-02: Approx. 240g F38PC-05: Approx. 440g F38PC-03: Approx. 300g |
Light receiving element | Ge photodiode |
---|---|
Sensitivity wavelength | 0.8~1.8μm |
Detecting temperature range | 2 ranges: Low temperature and high temperaure ranges (selectable with internal switch) |
STB function | Provided |
Digital display | Displaying light intensity (red LED) in three digits Displaying operation threshold (green LED) in two digits |
Indicator | Displaying output(OP.L): Orange LED Displaying stability (STB): Green LED Displaying simulation input (SIMU): Orange LED |
Display of deetcting temperaure range | High temperature range (Ht): Orange LED Low temperature range (Lt): Orange LED |
Received light intensity indication range | 0.0-12.0(in increments of 0.1) |
Setting range of operation threshold | 1.0-9.0(in incrementes of 0.1) |
Simulation input | ON: Short (leak current: 5mA or less) OFF: Released |