KD50W

Rating/Performance/ Specification/ Environmental Specification

Type Wide view type
Detection method Radiation detection
Power Supply 100 to 110VAC/200 to 220VAC ±10%% 50/60Hz
Power consumption 4W or less
Operation mode Light ON
Output mode Relay output
Rating: 1c 200 VAC 0.5A or less resistive load
Detection object temperature 450 ℃ or higher (standard steel material)(Fe=0.8)
Response time 25ms or less
Indicator Light reception indicator (red LED)
Sensitivity adjustment Adjustable with volume
Ambient temperature -10 ℃ to 55 ℃ (below 150 ℃ with water cooling)
Ambient humidity 35 to 85%RH (non-freezing, non-condensing)
Insulation resistance 500 VDC 20MΩ or more (between primary side of transformer/output terminal and case)
Dielectric withstanding 1.5 kVAC for 1 minute (between primary side of transformer/output terminal and case)
Vibration 10 to 55 Hz / 1.5 mm double amplitude / 2 hours each in 3 direction
Shock 500 m/s2 / twice each in 3 directions
Protective structure IP66
Case material Aluminum die cast
Connection Terminal block (cable opening : Ground hub)
Weight Approx. 2kg
Accessories Instruction manual, mounting bracked

Cooling water specification

Flow rate 2L/minute or more
Temperature +10 - +35℃
Withstand voltage 0.3MPa

Air purge specification (with optional part)

Flow rate 200L/minute or more
Withstand voltage 1MPa