Rating/Performance/ Specification/ Environmental Specification

Temperature of detected object 560 ℃ or higher
Output mode Relay output/voltage output
Rating: Relay output: 1c 250 VAC 5 A or less (resistive load)
Voltage output 12 VDC 5 mA or less
Operation mode Light ON (activated for presence of material)
Timer operation selectable, external gating
Timer: On delay, off delay, one shot, timer disabled (ON/OFF)
Time: Selectable between 0.1-1s and 1-10s (with switch)
Response time Relay output: 25ms; voltage output: 3ms
Power supply 100/110VAC・200/220VAC±10%, 50/60Hz
Power consumption 5VA or less
Connection Amplifier: Terminal block(3.5mm screws)
Sensor: Shielded cable 0.3mm2 x 1 core, length 2m
Ambient temperature (non-freezing) Amplifier: -10 ℃ to 50 ℃
Sensor: -25 ℃ to 50 ℃
Fiber: (Fiber tip: below 70 ℃)
Ambient humidity (non-condensing) Amplifier: 35-85%RH
Sensor: 35-85%RH
Fiber: 95%RH or less (20%RH or less at 70 ℃ or higher)
Insulation resistance Omitted (case grounded)
Dielectric withstanding Omitted (case grounded)
Vibration 10-55 Hz / 1.5 mm double amplitude / 2 hours each in 3 directions
Shock 500 m/s2 / 3 times each in 3 directions
Protective structure Amplifier: IP20
Sensor: IP66
Weight Amplifier: Approx. 450 g (including socket)
Sensor: Approx. 50 g (including cable)
Fiber allowable bending radius 10mm (except for 15mm from the tip)
Fiber material (covering) Glass (annealed stainless steel tube)