Detection method | Through |
---|---|
Detection distance | 20 to 60mm (optimum distance: 40mm) |
Operational power | 24VDC±10%, Ripple 10% or less |
Power consumption | 39mA or less |
Response time | 3ms or less |
Output mode | Analog output: 1 to 4V |
Operation mode | Output proportional to received ultrasonic intensity |
Ultrasonic frequency | 380kHz±15kHz |
Indicator | Transmitter: Power indicator (Green) Receiver: Power/Teaching error indicator (Blue) |
Operation method | Teaching type |
Auxiliary functions | Protection against reverse power connection |
Material | Case: SUS303, Detection surface: glass epoxy, polyurethane form, ABS |
Connection method | Attached cable: 3.5mm O.D. Transmitter: 0.15mm2×3 cores, 2m, Receiver: 0.15mm2×4 cores, 2m |
Weight | Approx. 130g (including cable) |
Accessories | Instruction Manual, Resin nut: 4 pcs (*1) |
*1: SUS nut (optional): Model: US-N2
Ambient temperature | -10 to +55℃ (no freezing) |
---|---|
Ambient humidity | 35 to 85%RH (no condensation) |
Protective structure | IP65 |
Vibration | 10 to 55Hz/1.5mm double amplitude/2 hours each in 3 directions (X,Y,Z) |
Shock | 300m/s2, 3 directions (X,Y,Z) for each three times |
Dielectric withstanding | 500VAC, one minute |
Insulation resistance | 500V megger, 20MΩ or more |