Detecting distance | 0.4 - 6m |
---|---|
Detection object | 500x500mm (2mm thick aluminum plate) |
Power supply | 12 - 24VDC ±10% / Ripple (p-p) 10% or less. |
Power consumption | 1.3W or less (current consumption: Approx.110mA or less (DC12V), Approx. 55mA (DC24V)) |
Response speed (standalone use) | 600ms or less |
Output mode | Analog: 4-20mA current output(applicable load:0-250Ω) for voltage output see *3 |
Minimum resolution *1 | 5.6mm (0.1%F.S.) |
Linearity | ± 1% F.S. |
Temperature characteristics | ± 1% of F.S. or less. with reference to output at 23 C between -10 and +55 C (±0.03% of F.S./ C or less) |
Ultrasonic frequency | Approx. 40kHz |
Indicator | RUN: (green) 4mA: (red) mid (orange) 20mA (green) |
Teaching system | Teaching: distance setting, output inversion (with SET button) |
Connection | Connector (M12) *2 |
Weight | Approx. 200 g |
Protective feature | Output short circuit protection, power supply output protection against reverse connection |
Auxiliary function | Anti interference, temperature correction |
Material | Case: Brass (nickel plated) Detection Side: ABS, urethane, Aluminum |
Accessories | Operation manual, voltage conversion resistance (250Ω),wave washers, nuts (Note :Cord with connector separately available) |
*1 Value applicable about 15 minutes after power-up. Output may be slightly fluctuated by external disturbance, etc. *2 Cable with M12 connector is separately available. *3 May be converted into voltage output (1-5 V) with the resistor (250 ホゥ) provided.
Ambient temperature | -10 - +55 ℃ (strage:-20 - +65 ℃) (non-freezing) |
---|---|
Ambient humidity | 35 - 85%RH (non-condensing) |
Ambient wind speed | 1 m/s or less |
Protective structure | IP67 (no drops of water allowed on head) |
Vibration | 10 - 55 Hz / 1.5 mm double amplitude / 2 hours each in 3 directions |
Shock | 500 m/s2 / 3 times each in 3 directions (ultrasonic element excluded) |
Dielectric withstanding | 1000VAC 50/60Hz for 1 minute |
Insulation resistance | 500 VDC, 50 MΩ or higher |