Detection method | Ultrasonic through |
---|---|
Power supply | 12 - 24V DC ±10% / Ripple 10% or less |
Current consumption | 60 mA or less |
Detection distance | 30 mm fixed |
Output voltage range | ±4mm of center |
Output mode | Analog output (1V to 5V within output voltage range, otherwise 6V or less) allowable load resistance:10kΩ or more *1 |
Response time | 100 ms or less |
Ultrasonic frequency | 40kHz |
Indicator | Output level indicator: five steps depending on the output voltage (green LED) |
Case Material | Case: ABS, Detection side: Aluminum |
Connection | Attached cord (φ4mm) 0.2 mm2 × 3 cores, 2 m |
Protection feature | Protection against reverse connection |
Weight | Approx. 150g |
Accessory | Operation manual |
*1 When the temperature is 25°C and the detection object is stainless steel plate (thickness 0.2mm)
Ambient temperature | 0 - +50°C/Storage: -30 - +70°C (non-freezing) |
---|---|
Ambient humidity | 35 - 85% RH (non-condensing) |
Protective structure | IP54 (no drops of water allowed on head) |
Vibration | 10-55 Hz / 1.5 mm double amplitude / 2 hours each in 3 direction |
Shock | 500 m/s2 / 3 times each in 3 directions |
Dielectric withstanding | 1000 VAC 50/60Hz for 1 minute |
Insulation resistance | 500 VDC, 50MΩ or higher |