| Detection method | Reflective |
|---|---|
| Detecting distance | 60-250mm |
| Detection object | 30 x 30mm* |
| Power supply | 24V DC ±10% / Ripple 10% or less |
| Current consumption | 25mA or less |
| Response time | ON: 30 ms or less / OFF: 50 ms or less |
| Output mode | Rating: Sink current 100 mA (30 VDC) or less |
| Operation mode | Detect ON |
| Hysteresis | 10% or less |
| Ultrasonic frequency | 380kHz ±15kHz |
| Indicator | Operation indicator (red LED) / Stability indicator (green LED) |
| Volume | Distance adjustment |
| Material | Case/nut : Heat resistant ABS resin Detection side : glass epoxy conductive EPDM |
| Connection | Attached cord(dia.4mm) : 0.2 mm2 x 3 cores, 2 m |
| Weight | 80 g or less |
| Accessory | Operation manual, mounting bracket,screw for adjustment |
*Sample object: 1-mm thick aluminum plate
| Ambient temperature | -10 - +55 ℃ (non-freezing) |
|---|---|
| Ambient humidity | 35-85%RH (non-condensing) |
| Ambient wind speed | 1m/s max. |
| Protective structure | IP54 (no drops of water allowed on head) |
| Vibration | 10 - 55 Hz / 1.5 mm double amplitude / 2 hours each in 3 directions |
| Shock | 500 m/s2 / 3 times each in 3 directions (ultrasonic element excluded) |