FD-A300PH

Output specification

Output type Signal relay output
Control output ON-OFF output
Operation mode:
Light ON/Dark ON selector switch provided (DIP switch)
Default setting: Light ON (output activated when light received)
Rating:
1c
0.5A 48VDC or less
(Resistive load)
*1)Response time:
Approx. 5ms (7ms)
Stability output Relay output 1a
*2 Rating: 5A 250VAC or less (Resistive load)

General specification

Valid lens diameter dia.28mm (OHA, OHAN, OHAN10)
Power Supply 100 - 220V AC +10%, -15% 50/60Hz
Power consumption 10W or less
Connection Cable with connector (CVV 1.25mm2, length 2m)
Ambient temperature Optical head, Fiber cable: -25 ℃ to 200 ℃
Amplifier: -25 ℃ to 50 ℃ (Non-freezing)
Storage temperature -40 ℃ to 70 ℃ (Non-condensing)
Ambient humidity 35 to 85%RH (Non-condensing)
Fibe optic cable 50mm
Insulation resistance Between power supply and case: 500 VDC, 20 MΩ or higher
Between output and case: 500 VDC, 20 MΩ or higher
Between power supply and output: 500 VDC, 20 MΩ or higher
Temperature range selection input: Omitted
Dielectric withstanding Between power supply and case: 1500VAC for 1 minute
Between output and case: 1500VAC for 1 minute
Between signal relay outputs: 1000VAC for 1 minute
Between power supply and output: 1500VAC for 1 minute
Between signal relay outputs: 1000VAC for 1 minute
Temperature range selection input: Omitted
Vibration 10-55 Hz / 1.5 mm double amplitude / 2 hours each in 3 direction
Shock 490 m/s2 / 3 times each in 3 directions
Protective structure IP66
Weight Optical head:
Standard view (OHA): Approx. 680g
Wide view (OHW1/OHW2): Approx. 1300g
Airless hood:
F38A: Approx. 240g F38A-04: Approx. 550g
F38A-02: Approx. 340g F38A-05: Approx. 650g
F38A-03: Approx. 430g F38W: Approx. 600g
Air purge hood:
F38PC-02: Approx. 240g F38PC-05: Approx. 440g
F38PC-03: Approx. 300g 302W: Approx. 600g
F38PC-04: Approx. 370g
Fiber optic cable:
FG2: Approx. 0.7㎏ FG50: Ap

Amplifier Major Specification

Light sensitive element Ge photodiode
Sensitivity wavelength 0.8 - 1.8μm
HMD function Auto sensing mode (automatic setting of operation level)
Manual mode (automatic setting of operation level)
Detecting temperature range 2 ranges: low temperature and high temperature ranges (selectable with external input)
Auxiliary function #NAME-
Indication - Output indictor (OP.L): Red LED / STB indicator (STB): Green LED
- Received light intensity display: 3-digit figure
Received light intensity scale range 0.1-10.0 (in increments of 0.1)
Operation level setting range Auto sensing mode: 1.0-8.0 (in increments of 0.1) / Manual mode: 1.0-9.0 (in increments of 0.1)