FT-L101 FT-R101

Output specification

Transmitter model FT-L101
Light source Infrared LED
Light emission monitor output Relay output 1c
Rating: 250VAC 2A or less (Resistive load)
Receiver model FT-R101
Operation mode Light ON / Dark ON (selectable with switch)
Response time 20ms or less

General specification

Detecting distance *Only Fiber
GT205AD:0.55m
GT21AD:0.55m
GT22AD:0.50m
GT23AD:0.45m
GT25AD:0.40m
GT27AD:0.35m
GT210AD:0.30m
*on FA51/52
GT205AD:2.7m
GT21AD:2.7m
GT22AD:2.5m
GT23AD:2.2m
GT25AD:2.0m
GT27AD:1.8m
GT210AD:1.5m
*on OHC
GT205AD:22m
GT21AD:22m
GT22AD:20m
GT23AD:18m
GT25AD:16m
GT27AD:14m
GT210AD:12m
*on OHA
GT205AD:45m
GT21AD:45m
GT22AD:40m
GT23AD:35m
GT25AD:30m
GT27AD:27m
GT210AD:25m
Fiber optic cable allowable bending radius 50mm
Power Supply 100-240 VAC ±10%, 50/60 Hz
Power consumption Transmitter: 2 W or less Receiver: 2 W or less
Indicator Transmitter: Power indicator: Green LED, Monitor indicator: Red LED
Receiver: operation indicator: Red LED, Level indicator: Level1・2:
Yellow Led level 3: Green LED
Connection Terminal block (screw: M3.5, width: 8.1mm)
Ambient temperature Optical head, Fiber: -25 ℃ to 200 ℃
Amplifier: -25 ℃ to 55 ℃ (Non-freezing)
Storage temperature -40 ℃ to 70 ℃ (Non-freezing, non-condensing)
Ambient humidity 35 -85%RH (Non-condensing)
Ambient light 10000 lx (incandescent lamp)
Protective structure IP66
Vibration 10-55 Hz / 1.5 mm double amplitude / 2 hours each in 3 directions
Shock 500 m/s2 / 3 times each in 3 directions
Dielectric withstanding Input/Output - Case, Input - Output
2000VAC for 1 minute
Insulation resistance 500 VDC 20MΩ or higher
Case material Zinc die-cast
Weight Transmitter: Approx.720g, Receiver : Approx.720g
Accessories Operation manual, Mounting bracket