| Detection method | Through beam | 
|---|---|
| Detecting distance | 50m | 
| Detectiing object | dia.22mm or more | 
| Power Supply | 100 - 240VAC ±10% 50/60Hz | 
| Current consumption / Power consumption | Transmitter: 5W or less / Receiver: 5W or less | 
| Output mode | Relay output 1c Rating: 250VAC 2A or less (resistive load)  | 
                        
| Operation mode | Light ON/Dark ON (selectable with switch) | 
| Light monitor | Relay contact output 1c Rating: 250V AC 2A or less (resistive load)  | 
                        
| Response time | 20ms or less | 
| Light source | Infrared LED (wave length 910nm) | 
| Indicator | (Transmitter) P.L: Power indicator (green LED) … Illuminated when power on OP.L: Monitor indicator (red LED) … Illuminated when emit light normally (Receiver) OP.L: Operation indicator (red LED) …Illuminated when output on LEVEL: Level indicator (three level display) LEVEL1: yellow LED illuminated when light intensity of about twice as much as operation level is detected. LEVEL2: yellow LED illuminate  | 
                        
| Switch (SW) | Light ON/Dark ON Remove the case lid of the receiver Light ON … Output at light receiving selector switch provided to access the switch. Dark ON … Output at light blocking  | 
                        
| Materials | Case: Zinc die cast | 
| Connection | Terminal block (screw: M3.5, width: 8.1mm) | 
| Weight | Transmitter: Approx. 700g Receiver: Approx. 700g  | 
                        
| Accessories | Operation manual, Mounting bracket | 
*1 When the light intensity is LEVEL 1 or lower, the alarm is output (yellow LED turns off).
| Ambient light (on light receiving surface) | 050,000 lx or less (incandescent lamp) 100,000 lx or less (sunlight)  | 
                        
|---|---|
| Ambient temperature | -25 - +55 ℃ (Non-freezing) | 
| Storage temperature | -40 - +70 ℃ (Non-condensing) | 
| Ambient humidity | 35 - 85%RH (Non-condensing) | 
| Protective structure | IP66 | 
| Vibration | 10-55 Hz / 1.5 mm double amplitude / 2 hours each in 3 directions | 
| Shock | 500 m/s2 / 3 times each in 3 directions | 
| Dielectric withstanding | 2000 VAC for 1 minute (between input/output and case) | 
| Insulation resistance | 500 VDC, 20 MΩ or higher | 
*1 When the light intensity is LEVEL 1 or lower, the alarm is output (yellow LED turns off).