SWD60

Rating/Performance/Specification

Transmitter SWD60T
Receiver SWD60R
Detecting distance 250-1000 mm between transmitter and receiver (500 mm recommended)
Effective detecting width 470mm
Light source Infrared LED
Power supply Supplied by controller (24 VDC (20-30 V), ripple 10% or less)
Current consumption Transmitter: 280 mA or less; Receiver: 210 mA or less
Ambient temperature -25 ℃ to 55 ℃ (below 80 ℃ with water cooling)
Storage temperature -40 ℃ to 70 ℃ (Non-freezing)
Ambient humidity 35 - 85%RH (Non-condensing)
Vibration 10-55 Hz / 1.5 mm double amplitude / 2 hours each in 3 directions
Shock 500 m/s2 / 3 times each in 3 directions
Connection Metal connector (cable: 2 m)
Protective structure IP66
Weight Transmitter: Approx. 2.6 kg (including 2m cable)
Receiver: Approx. 2.9 kg (including 2m cable)
Air purge unit: Approx. 0.3 kg
Water cooling jacket: Approx. 1.7 kg.

Rating/Performance/Specification (Controller)

Single-hole detection output Relay output 1c and NPN open collector output (floating)
Double-hole detection output Relay output 1c and NPN open collector output (floating)
Output rating Relay output: 250 VAC 5 A or less (resistive load)
NPN Open collector output: 30VDC 100mA or less
Operation mode One shot output: duration variable between 0.1-1 second (adjustment volume on panel)
Response time Relay output: 30 ms or less
NPN Open collector output: 3ms or less
SAFETY output Relay output 1a
Output rating: 250 VAC 5 A or less (resistive load)
ALARM output operation mode Output rating: Relay output 250VAC 5A or less (resistive load)
Receiver check input a (normally open) contact input (short circuiting of Terminals 9 and 10)
Power supply 100, 110, 200 or 220 VAC
(rated voltage: -15+10%, 50/60 Hz)
Power consumption 30W or less
Ambient temperature -25C to 55 C (Non-freezing)
Storage temperature -40C to 70 C (Non-condensing)
Ambient humidity 35 - 85%RH (Non-condensing)
Dielectric withstanding/Insulation resistance Between power supply and case 1500 VAC for 1 minute
Between relay output and case 20 MΩ or higher
Between relay output and power supply (with 500 VDC)
Between open collector output and case 1000 VAC for 1 minute
Between open collector output and power supply 20 MΩ or higher
(with 250 VDC)
Vibration 10-55 Hz / 1.5 mm double amplitude / 2 hours each in 3 directions
Shock 500 m/s2 / 3 times each in 3 directions
Connection Terminal block
Protective structure IP40 (with case)
Weight Approx. 9kg