| Detection method | Through |
|---|---|
| Detection distance | 20 to 60mm (optimum distance: 40mm) |
| Operational power | 24VDC±10%, Ripple 10% or less |
| Power consumption | 39mA or less |
| Response time | 3ms or less |
| Output mode | Analog output: 1 to 4V |
| Operation mode | Output proportional to received ultrasonic intensity |
| Ultrasonic frequency | 380kHz±15kHz |
| Indicator | Transmitter: Power indicator (Green) Receiver: Power/Teaching error indicator (Blue) |
| Operation method | Teaching type |
| Auxiliary functions | Protection against reverse power connection |
| Material | Case: SUS303, Detection surface: glass epoxy, polyurethane form, ABS |
| Connection method | Attached cable: 3.5mm O.D. Transmitter: 0.15mm2×3 cores, 2m, Receiver: 0.15mm2×4 cores, 2m |
| Weight | Approx. 130g (including cable) |
| Accessories | Instruction Manual, Resin nut: 4 pcs (*1) |
*1: SUS nut (optional): Model: US-N2
| Ambient temperature | -10 to +55℃ (no freezing) |
|---|---|
| Ambient humidity | 35 to 85%RH (no condensation) |
| Protective structure | IP65 |
| Vibration | 10 to 55Hz/1.5mm double amplitude/2 hours each in 3 directions (X,Y,Z) |
| Shock | 300m/s2, 3 directions (X,Y,Z) for each three times |
| Dielectric withstanding | 500VAC, one minute |
| Insulation resistance | 500V megger, 20MΩ or more |