| Power supply | 12 to 24VDC, class 2 * / Ripple 10% or less |
|---|---|
| Power consumption | Normal mode: 770 mW or less (32 mA or less at 24 V) ECO mode: 600 mW or less (25 mA or less at 24 V) |
| Control output | NPN open collector output / Load current 100 mA (30VDC, class 2) or less / Residual voltage: 1 V or less PNP open collector output / Load current 100 mA (30VDC, class 2) or less / Residual voltage: 2 V or less |
| Operation mode | Light ON / Dark ON |
| Timer | ON delay, OFF delay, ON/OFF delay, One-shot, Timer off Delay timer: 1 ms – 9999 ms (set in millisecond) |
| Response time | H-SP mode: 65 µs or less / Stnd mode: 500 µs or less / LonG mode: 4 ms or less |
| Light source (wavelength) | Four-element (AlGaInp) LED (660 nm) |
| Indicator | Operation indicator, Setting/Teaching indicator, Light ON/Dark ON indicator: orange LED |
| Display | Received light level: 4 digits in red LED (high-speed mode (0 -3800), standard/long mode (0 - 9999)) Threshold: 4 digits in green LED (high-speed mode (0 -3500), standard/long mode (0 - 9700)) |
| Switch | Teaching and setting (SET) Threshold adjustment and select settings (UP/DOWN) |
| Sensitivity setting | 2-point teaching / Max. sensitivity teaching / Full auto teaching / Positioning teaching |
| Sensitivity adjustment function | Provided |
| Light source level adjustment | Provided (auto/manual) |
| Mutual Interference prevention | UP to 8 units (standard and long modes only) |
| Protection circuit | Power reverse connection / Output short circuit protection |
| Material | Polycarbonate |
| Wiring | M8 connector (cables are sold seperately) |
| Weight | Approx. 22 g |
| Accessory | Instruction maual, QR label for handy manual download |
* When using as UL approved equipment.
| Ambient light | Illumination on light receiving surface: 3,500 lx or less (incandescent lamp) |
|---|---|
| Ambient temperature | 1 to 5 adjacent units in operation : -25 to +55°C 6 to 26 adjacent units in operation : -25 to +50°C *1 Storage : -40 to +70°C (non-freezing, non-condensing) |
| Ambient humidity | 35 to 85% RH (non-condensing) |
| Protective structure | IP40 |
| Vibration | 10 to 55 Hz / 1.5 mm double amplitude / 2 hours each in X, Y, and Z directions |
| Shock | 500 m/s2 / 3 times each in X, Y and Z directions |
| Dielectric withstanding | 1000 VAC for 1 minute |
| Insulation resistance | 500 VDC mega, 20 MΩ or more |
*1 : UL: Maximum ambient temperature: +55℃ for single use, +45℃ for two or more units connected installation.