| Detection method | CCD scanning |
|---|---|
| Detectable temperature | 680℃ or higher |
| Field of view | 800mm / 1m |
| Resolution capacity | Field of view ×1 / 256 |
| Diameter of minimum detectable object |
Field of view ×2 / 256 or more |
| Power supply | 24 VDC ±10% ripple 10% or less |
| Current consumption | 200mA or less |
| Output mode | [Analog voltage] Rated voltage: 0 to 10 VDC, ±5% Output impedance: 47Ω [Control output (Work presence output)] NPN open collector 2 outputs Rated voltage: Sink current 100mA (30 VDC) or less ※Automatic reset fuse |
| Operational mode | Voltage output in proportion to the position of radiation |
| Response time | 10 ms or less Control (work presence) output 1, 2 |
| Indicators | Power indicator (Green LED) Work presence indicator (Red LED) |
| Adjustment function | Operation check switch SENS1 input (sensitivity setting) SENS2 input (sensitivity setting) |
| Monitoring function | Video monitor output, Slice timing monitor output |
| Material | Enclosure: aluminum / Lens: glass |
| Connection | Connector (twisted pair cable) |
| Weight | Approx. 5kg |
| Accessories | Instruction manual |
| Ambient illuminance | 500lx or less |
|---|---|
| Ambient temperature | -10 to +55℃ (no freezing, no condensation) At water-cooling: +80℃ |
| Ambient humidity | 35 to 85%RH |
| Protection structure | IP66 |
| Anti-vibration | 10 to 55Hz, double amplitude 1.5mm X, Y, Z directions, 2 hours each |