SS10A-T96-CH

Rating/Performance/Specification

Detecting distance 3m
Detecting object ø17mm (Min.) Opaque object
Number of optical axes 96
Detecting width 950mm
Beam interval 10mm
Power supply 24V DC ±10%, Ripple: 10% or less
Current consumption 220mA or less
Output mode Individual output for each optical axis: serial output
Versatile output: NPN open collector output
Rating: Sink current 100mA (at up to 30V DC)
Operation mode Individual output for each optical axis: Serial output
Versatile output: ON only when receiving all optical axes
Response time Individual output for each optical axis: 40ms or less (for SS10A only)
When combined with B-1304/MA/SA: 45ms or less
Versatile output: 25ms or less
Light source Infrared LED
Indicators Transmitter: M/S indicator (Orange LED), Power indicator (Green LED)
Receiver: Light stability indicator (Green LED), Operation indicator (Orange LED)
Switches Transmitter: M/S operation switch: integrated with the rear screw (M: master operation, S: slave operation)
Receiver: Output operation switch: integrated with the rear screw (NOR: Versatile output:, SEP: Individual output for each optical axis)
Auxiliary functions Mutual interference prevention when sensors are mounted in close proximity to each other.
Power reverse connection prevention. Output short-circuit protection.
Materials Case: Aluminum, Front cover and lens: PMMA, Caps at both ends: PBT
Connection method Attached cable with connector (length: 0.2m)
Attached cable with connector: 0.5mm2 × 4-core, ø6.8mm o.d.
Weight Transmitter / Receiver: Approx. 250g to 800g
Conversion board B-1304MA/SA *Output operation for each light axis (separately sold)
Accessory Attached cable with connector (length: 5m, Weight: approx. 350g), Instruction manual

Environmental Specification

Ambient light 9,000 lx or less
Ambient temperature -10 to +55˚C (at storage), -30 to +70˚C (non-freezing or non-condensing)
Ambient humidity 35 to 85%RH (non-condensing)
Protective structure IP66
Vibration 10 to 55Hz, double amplitude 1.5 mm, X, Y, Z directions, 2 hours each
Shock 500 m/s2, 3 times each in X, Y and Z directions
Dielectric withstand voltage 500V AC for 1 min
Insulation resistance At least 20MΩ with 500V DC Megger

This product includes parts for noise attenuation which are connected between the housing and the battery charging section to prevent erroneous operation due to noise.
The dielectric withstand voltage and the insulation resistance values quoted in the specifications are with these attenuators removed.