| Detection method | Limited range reflective |
|---|---|
| Detecting distance | 0.1 - 1m (with adjustment at or less) |
| Setting distance | 0.2 - 1m (with 200×200mm white drawing paper) |
| Power supply | 12-24V DC ±0% / Ripple 10% or less |
| Current consumption | 30mA or less |
| Output mode | NPN/PNP open collector 2 outputs Rating: 100 mA (30 VDC) or less NPN: sink current / PNP: source current |
| Operation mode | Light ON/Dark ON selectable (with switch) |
| Response time | 2 ms or less |
| Hysterisis | 10% of detecting distance or less |
| Light source (light wavelength) | Red LED (650 nm) |
| Light receiving element | 2 segment photodiode |
| Indicator | Red LED: Operation indicator / Green LED: Stability indicator |
| Volume(VR) | NEAR/FAR: 5-turn optical distance adjustment |
| Switch(SW) | Light ON/Dark ON selector switch |
| Short circuit protection | Provided |
| Material | Case and lens: polyarylate |
| Connection | M8 4 pin connector pigtail Outer dimension: dia.4mm 0.2mm2 4 cores |
| Weight | Approx. 60g |
| Accessories | Operation manual *The mounting bracket and the cable with connector are separately available. |
| Ambient light | Sunlight: illumination on light receiving surface 10,000 lx or less Incandescent lamp: illumination on light receiving surface 3,000 lx or less |
|---|---|
| Ambient temperature | -25 - +55 ℃ (non-freezing) |
| Ambient humidity | 35-85%RH (non-condensing) |
| Protective structure | IP66 |
| Vibration | 10-55 Hz / 1.5 mm double amplitude / 2 hours each in 3 directions |
| Shock | 500 m/s2 / 3 times each in 3 directions |
| Dielectric withstanding | 1,000 VAC for 1 minute |
| Insulation resistance | 500 VDC, 20 MΩ or higher |