製品情報

SWD60B
Controller

Download

Dimension

product.model

Specifications

Description Controller
Control output Single-hole detection output : Relay output 1c and NPN open collector output (floating)
Double-hole detection output : Relay output 1c and NPN open collector output (floating)
Output rating Relay output : 250 VAC 5 A or less (resistive load)
NPN Open collector output : 30VDC 100mA or less
Operation mode One shot output : duration variable between 0.1-1 second (adjustment volume on panel)
Response time Relay output : 30 ms or less
NPN Open collector output : 3ms or less
SAFETY output Relay output 1a
Output rating : 250 VAC 5 A or less (resistive load)
ALARM output operation mode Output rating : Relay output 250VAC 5A or less (resistive load)
Receiver check input a (normally open) contact input (short circuiting of Terminals 9 and 10)
Power supply 100, 110, 200 or 220 VAC
(rated voltage : ?15+10%, 50/60 Hz)
Power consumption 30W or less
Ambient temperature -25°C to 55 °C (Non-freezing)
Storage temperature -40°C to 70 °C (Non-condensing)
Ambient humidity 35 - 85%RH (Non-condensing)
Dielectric withstanding/Insulation resistance Between power supply and case
Between relay output and case
Between relay output and power supply
1500 VAC for 1 minute, 20 MΩ or higher (with 500 VDC)

Between open collector output and case
Between open collector output and power supply
1000 VAC for 1 minute, 20 MΩ or higher (with 250 VDC)
Vibration 10-55 Hz / 1.5 mm double amplitude / 2 hours each in 3 directions
Shock 500m/s2/ 3 times each in 3 directions
Connection Terminal block
Protective structure IP40 (with case)
Weight Approx. 9 ㎏