SWD60B
Controller
Dimension

Specifications
Description | Controller |
---|---|
Control output | Single-hole detection output : Relay output 1c and NPN open collector output (floating) Double-hole detection output : Relay output 1c and NPN open collector output (floating) |
Output rating | Relay output : 250 VAC 5 A or less (resistive load) NPN Open collector output : 30VDC 100mA or less |
Operation mode | One shot output : duration variable between 0.1-1 second (adjustment volume on panel) |
Response time | Relay output : 30 ms or less NPN Open collector output : 3ms or less |
SAFETY output | Relay output 1a Output rating : 250 VAC 5 A or less (resistive load) |
ALARM output operation mode | Output rating : Relay output 250VAC 5A or less (resistive load) |
Receiver check input | a (normally open) contact input (short circuiting of Terminals 9 and 10) |
Power supply | 100, 110, 200 or 220 VAC (rated voltage : ?15+10%, 50/60 Hz) |
Power consumption | 30W or less |
Ambient temperature | -25°C to 55 °C (Non-freezing) |
Storage temperature | -40°C to 70 °C (Non-condensing) |
Ambient humidity | 35 - 85%RH (Non-condensing) |
Dielectric withstanding/Insulation resistance | Between power supply and case Between relay output and case Between relay output and power supply 1500 VAC for 1 minute, 20 MΩ or higher (with 500 VDC) Between open collector output and case Between open collector output and power supply 1000 VAC for 1 minute, 20 MΩ or higher (with 250 VDC) |
Vibration | 10-55 Hz / 1.5 mm double amplitude / 2 hours each in 3 directions |
Shock | 500m/s2/ 3 times each in 3 directions |
Connection | Terminal block |
Protective structure | IP40 (with case) |
Weight | Approx. 9 ㎏ |